<strong>VTrak</strong> E-<strong>Class</strong> <strong>Product</strong> <strong>Manual</strong><br />

Managing the Subsystem<br />

Subsystem Management includes the following functions:<br />

• Setting an Alias for the Subsystem (page 152)<br />

• Setting Redundancy for the Subsystem (page 152)<br />

• Setting Cache Mirroring for the Subsystem (page 152)<br />

• Running Media Patrol (page 153)<br />

• Locking or Unlocking the Subsystem (page 153)<br />

• Setting Subsystem Date and Time (page 154)<br />

Setting an Alias for the Subsystem<br />

An alias is optional. To set an Alias for this subsystem:<br />

1. From the Main Menu, highlight Subsystem Management and press Enter.<br />

2. Type and alias into the Alias field.<br />

Maximum of 48 characters. Use letters, numbers, space between words<br />

and underscore.<br />

3. Press Ctrl-A to save your settings.<br />

Setting Redundancy for the Subsystem<br />

This feature applies to models with dual controllers.<br />

To set redundancy:<br />

1. From the Main Menu, highlight Subsystem Management and press Enter.<br />

2. Highlight Redundancy Type and press the spacebar to toggle between<br />

Active-Active and Active-Standby.<br />

• Active-Active – Both RAID controllers are active and can share the load<br />

• Active-Standby – One RAID controller is in standby mode and goes<br />

active if the other fails<br />

3. Press Ctrl-A to save your settings.<br />

Setting Cache Mirroring for the Subsystem<br />

This option applies only to subsystems with two controllers. To use Cache<br />

Mirroring, the Redundancy Type must be set to Active-Active.<br />

To change Cache Mirroring for this subsystem:<br />

1. From the Main Menu, highlight Subsystem Management and press Enter.<br />

2. Highlight Redundancy Type and press the spacebar to toggle between<br />

Active-Active and Active-Standby.<br />