<strong>VTrak</strong> E-<strong>Class</strong> <strong>Product</strong> <strong>Manual</strong><br />

Reported Event Corrective Action<br />

Blowers have been<br />

removed<br />

Blowers are functioning<br />

normally<br />

Reinstall the cooling unit(s). If the blowers does not<br />

turn, replace the blowers. See page 219.<br />

Normal.<br />

Blowers are NOT installed Reinstall the cooling unit(s). If the blowers does not<br />

turn, replace the blowers. See page 219.<br />

Blower status is unknown Check for airflow out of the cooling unit. If there is<br />

none, check for proper installation.<br />

Cache<br />

BBU flushing has started <strong>VTrak</strong>’s cache is being flushed.<br />

BBU flushing has ended <strong>VTrak</strong>’s cache has been flushed.<br />

BBU flushing has failed <strong>VTrak</strong>’s cache could not be flushed. Check your<br />

cache flush interval setting. See page 107.<br />

Controller<br />

The controller<br />

parameter(s) changed by<br />

user<br />

The controller has new<br />

crash information<br />

Controller temperature is<br />

above the threshold/<br />

warning threshold<br />

Controller temperature is<br />

above the critical<br />

threshold<br />

Disk Array<br />

New disk array has been<br />

created<br />

Disk array has been<br />

deleted<br />

Disk array has been<br />

added<br />

Disk array has been<br />

removed<br />

The user successfully change controller settings. See<br />

page 107.<br />

Check the event logs. See page 63.<br />

The <strong>VTrak</strong> controller is overheating. Check for airflow<br />

around and through the controller, and verify that all<br />

fans are working. Replace fans as needed.<br />

The <strong>VTrak</strong> controller is seriously overheating. Check<br />

for airflow around and through the controller, and<br />

verify that all fans are working. Replace fans as<br />

needed.<br />

Result of settings or user action. Normal.<br />

Result of settings or user action. Normal.<br />

Result of settings or user action. Normal.<br />

The physical drives of the disk array were removed<br />

from the enclosure.<br />