<strong>Is</strong> <strong>it</strong> <strong>necessary</strong> <strong>to</strong> <strong><strong>in</strong>stall</strong> a <strong>downhole</strong> <strong>safety</strong> <strong>valve</strong> <strong>in</strong> a <strong>subsea</strong> oil/gas well?<br />
Table 3-2 Safety <strong>in</strong>tegr<strong>it</strong>y levels for <strong>safety</strong> functions operat<strong>in</strong>g on demand or <strong>in</strong> a cont<strong>in</strong>uous demand mode<br />
from IEC 61508-1, Table 2 and 3)[28]<br />
Safety<br />
Integr<strong>it</strong>y<br />
Level (SIL)<br />
Demand Mode of Operation<br />
(average probabil<strong>it</strong>y of failure <strong>to</strong><br />
perform <strong>it</strong>s design function on<br />
demand –PFD)<br />
Cont<strong>in</strong>uous / High Demand<br />
Mode of Operation<br />
(probabil<strong>it</strong>y of a dangerous<br />
failure per hour)<br />
4 ≥ 10 -5 <strong>to</strong> < 10 -4 ≥ 10 -9 <strong>to</strong> < 10 -8<br />
3 ≥ 10 -4 <strong>to</strong> < 10 -3 ≥ 10 -8 <strong>to</strong> < 10 -7<br />
2 ≥ 10 -3 <strong>to</strong> < 10 -2 ≥ 10 -7 <strong>to</strong> < 10 -6<br />
1 ≥ 10 -2 <strong>to</strong> < 10 -1 ≥ 10 -6 <strong>to</strong> < 10 -5<br />
An extract of the m<strong>in</strong>imum SIL requirements given <strong>in</strong> ref. [28] relat<strong>in</strong>g <strong>to</strong> the object of this<br />
thesis is presented <strong>in</strong> Table 3-3. The SIL requirement concern<strong>in</strong>g the shut-<strong>in</strong> of the flow <strong>in</strong> a<br />
well (W<strong>in</strong>g <strong>valve</strong>, Master <strong>valve</strong> and DHSV) is set <strong>to</strong> 3. It is therefore reasonable <strong>to</strong> also require<br />
a SIL3 for a well w<strong>it</strong>hout a DHSV.<br />
Table 3-3 M<strong>in</strong>imum SIL requirements - global <strong>safety</strong> functions, an extract [28]<br />
Safety function SIL Functional boundaries for given SIL<br />
requirement / comments<br />
<strong>Is</strong>olation of well;<br />
(shut <strong>in</strong> of one well)<br />
3 The SIL requirement applies <strong>to</strong> the sub-function<br />
needed for isolation of one well, i.e:<br />
- ESD-node (wellhead control panel)<br />
- W<strong>in</strong>g <strong>valve</strong> (WV) and master <strong>valve</strong> (MV)<br />
<strong>in</strong>clud<strong>in</strong>g solenoide(s) and actua<strong>to</strong>rs<br />
- Downhole <strong>safety</strong> <strong>valve</strong> (DHSV) <strong>in</strong>clud<strong>in</strong>g<br />
solenoide(s) and actua<strong>to</strong>r<br />
Diploma thesis, <strong>NTNU</strong> 2002<br />
Ref.<br />
APP. A<br />
A.6<br />
10