Chapter 4 Experimental Data Analysis<br />

This chapter presents the analysis <strong>of</strong> the data from the experiments carried out in the<br />

large-scale geotechnical test box. The first part <strong>of</strong> the chapter explains the preparation <strong>of</strong> test<br />

sections. The second part presents data obtained from the tests in a graphical form. At the end <strong>of</strong><br />

this chapter, the comparison <strong>of</strong> the results from different test sections is presented.<br />

4.1 Preparation <strong>of</strong> Test Sections<br />

4.1.1 Subgrade<br />

The subgrade consisted <strong>of</strong> a mixture <strong>of</strong> 75% Kansas River (KR-I) s<strong>and</strong> <strong>and</strong> 25% kaolin.<br />

The target CBR value <strong>of</strong> the subgrade was 5%, which represents an intermediate stiff subgrade<br />

for pavement applications. The previous discussion in Chapter 3 showed that the CBR <strong>of</strong> 5%<br />

occurred at the moisture content close <strong>to</strong> the optimum moisture content (OMC) <strong>of</strong> 10.4%. These<br />

two materials were mixed in proportion manually on a platform <strong>to</strong> achieve a homogeneous dry<br />

mixture. Water was added <strong>to</strong> the mixture <strong>and</strong> mixed again with water <strong>to</strong> achieve water content<br />

slightly higher than the OMC <strong>of</strong> 10.4%. The prepared mixture was set for more than 24 hours <strong>to</strong><br />

allow uniform distribution <strong>of</strong> moisture in the mass.<br />

The <strong>to</strong>tal thickness <strong>of</strong> the subgrade was 90 cm The prepared mixture was placed inside<br />

the large box in a lift thickness <strong>of</strong> 15 cm for six lifts, <strong>and</strong> its moisture content was checked for<br />

each lift If the moisture content differed from the required one, the moisture content <strong>of</strong> the<br />

subgrade was adjusted by adding more water or by allowing it <strong>to</strong> dry. The placed subgrade soil<br />

was then compacted by a vibra<strong>to</strong>ry plate compac<strong>to</strong>r for several passes until the average vane<br />

shear strength reached the desired value. Vane shear tests were conducted at five different<br />

locations. The average undrained shear strength obtained from the vane shear tests was used <strong>to</strong><br />

estimate the subgrade CBR value based on the correlation described in section 3.6.6.<br />