02.07.2013 Views

Type III C lass A Program

Type III C lass A Program

Type III C lass A Program

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

issuing a KO or a CLROVER command. When additional SETOVER<br />

commands are issued, the option settings are adjusted to<br />

reflect those specified in the most recent SETOVER command.<br />

If SAMELAST is not specified as the first option in these<br />

additional commands, the options are reset to their default<br />

settings, and only those options specified by the user in<br />

the new SETOVER command replace the default settings.<br />

""<br />

To terminate overrides set by the SETOVER command, the user<br />

may issue a KO or a CLROVER command. Both CLROVER and KO<br />

cause all trace information recorded up to the point they<br />

are issued to be printed on the offline printer. CLROVER<br />

can be issued only when the keyboard is unlocked to accept<br />

input to the CMS Command environment,. To clear overrides at<br />

any other point in system processing, KO must be issued. If<br />

a user issues a RESTART request to the Debug environment or<br />

logs" out from the Control PrograF prior to clearing<br />

overrides set by SETOVER and/or SETERR. the overrides are<br />

cleared automatcially and all recorded trace information is<br />

printed on the offline printer.<br />

Notes:<br />

a. If SAMELAST is specified, it must be the first option<br />

given and there must be no intervening CLROVER between the<br />

two SETOVER commands.<br />

b. If mutually exclusive options are specified, such as<br />

NOPARM and PARM1, the last such option appearing in the<br />

SETOVER command is used. For options which are not mutually<br />

exclusive--GPRS and GPRSA, for example--the logical<br />

combination of the options is used. In this case, the<br />

option set by GPRS would be used since it includes the GPRSA<br />

option.<br />

c. The number of lines of parameter list information<br />

recorded for calls to the WAIT routine cannot exceed that<br />

recorded for other routines, (that is, the" PARM setting<br />

governs the WAIT setting when the latter specifies the<br />

greater number of lines to be recorded.<br />

Responses:<br />

None.<br />

output:<br />

SETTING NORMAL - AND ERROR-OVERRIDES TO PROVIDE<br />

A DYNAMIC TRACE OF CMS (AND OS> SVC-CALLS... • •<br />

This message appears in the offline printout of trace<br />

information at all points where SETOVER commands are issued.<br />

Examples:<br />

a. SETOVER<br />

In addition to the basic information recorded for both<br />

SETOVER 263

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!