8.1 Output filter with component details . . . . . . . . . . . . . . . . . . . . . 103<br />

8.2 Comparison <strong>of</strong> Measured input DM emissions: without and with output<br />

EMI filter (115V-400Hz to 80V-50Hz) . . . . . . . . . . . . . . . . . . . . . 104<br />

8.3 Comparison <strong>of</strong> Measured input DM emissions: without and with output<br />

EMI filter (115V-400Hz to 80V-100Hz) . . . . . . . . . . . . . . . . . . . . 104<br />

8.4 Comparison <strong>of</strong> Measured input CM emissions: without and with output<br />

EMI filter (115V-400Hz to 80V-50Hz) . . . . . . . . . . . . . . . . . . . . . 105<br />

8.5 Comparison <strong>of</strong> Measured input CM emissions: without and with output<br />

EMI filter (115V-400Hz to 80V-100Hz) . . . . . . . . . . . . . . . . . . . . 105<br />

8.6 Comparison <strong>of</strong> Measured input DM emissions: without and with output<br />

EMI filter (240V-50Hz to 168V-50Hz) . . . . . . . . . . . . . . . . . . . . . 106<br />

8.7 Comparison <strong>of</strong> Measured input DM emissions: without and with output<br />

EMI filter (240V-50Hz to 168V-100Hz) . . . . . . . . . . . . . . . . . . . . 106<br />

8.8 Comparison <strong>of</strong> Measured input CM emissions: without and with output<br />

EMI filter (240V-50Hz to 168V-50Hz) . . . . . . . . . . . . . . . . . . . . . 106<br />

8.9 Comparison <strong>of</strong> Measured input CM emissions: without and with output<br />

EMI filter (240V-50Hz to 168V-100Hz) . . . . . . . . . . . . . . . . . . . . 107<br />

8.10 Comparison <strong>of</strong> Measured output DM emissions: without and with out-<br />

put EMI filter (115V-400Hz to 80V-50Hz) . . . . . . . . . . . . . . . . . . . 107<br />

8.11 Comparison <strong>of</strong> Measured output DM emissions: without and with out-<br />

put EMI filter (115V-400Hz to 80V-100Hz) . . . . . . . . . . . . . . . . . . 108<br />

8.12 Comparison <strong>of</strong> Measured input CM emissions: without and with output<br />

EMI filter (115V-400Hz to 80V-50Hz) . . . . . . . . . . . . . . . . . . . . . 108<br />

8.13 Comparison <strong>of</strong> Measured input CM emissions: without and with output<br />

EMI filter (115V-400Hz to 80V-100Hz) . . . . . . . . . . . . . . . . . . . . 108<br />

8.14 Comparison <strong>of</strong> Measured output DM emissions: without and with out-<br />

put EMI filter (240V-50Hz to 168V-50Hz) . . . . . . . . . . . . . . . . . . . 109<br />

8.15 Comparison <strong>of</strong> Measured output DM emissions: without and with out-<br />

put EMI filter (240V-50Hz to 168V-100Hz) . . . . . . . . . . . . . . . . . . 109<br />

8.16 Comparison <strong>of</strong> Measured input CM emissions: without and with output<br />

EMI filter (240V-50Hz to 168V-50Hz) . . . . . . . . . . . . . . . . . . . . . 110<br />

8.17 Comparison <strong>of</strong> Measured input CM emissions: without and with output<br />

EMI filter (240V-50Hz to 168V-100Hz) . . . . . . . . . . . . . . . . . . . . 110<br />