PDF (Thesis) - Nottingham eTheses - University of Nottingham
PDF (Thesis) - Nottingham eTheses - University of Nottingham
PDF (Thesis) - Nottingham eTheses - University of Nottingham
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
CHAPTER 5: EMI MEASUREMENTS<br />
Motor current phase U [A]<br />
1.5<br />
1<br />
0.5<br />
0<br />
−0.5<br />
−1<br />
q = 0.6<br />
q = 0.7<br />
q = 0.8<br />
−1.5<br />
0 5 10 15 20 25 30 35 40<br />
Time [ms]<br />
I[dBµA]<br />
I[dBµA]<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
Motor current phase U [A]<br />
1<br />
0.9<br />
0.8<br />
0.7<br />
0.6<br />
0.5<br />
0.4<br />
0.3<br />
0.2<br />
0.1<br />
q = 0.6<br />
q = 0.7<br />
q = 0.8<br />
0<br />
0 50 100 150 200 250 300 350<br />
Frequency [Hz]<br />
Figure 5.12: Output current for different values <strong>of</strong> modulation index q<br />
10<br />
0<br />
−10<br />
q = 0.6<br />
q = 0.7<br />
q = 0.8<br />
Limit Cat L<br />
0.1 1 10<br />
Frequency [MHz]<br />
100<br />
80<br />
60<br />
40<br />
20<br />
Figure 5.13: DM EMI at Matrix converter input varying q<br />
0<br />
−20<br />
q = 0.6<br />
q = 0.7<br />
q = 0.8<br />
Limit Cat L<br />
0.1 1 10<br />
Frequency [MHz]<br />
Figure 5.14: CM EMI at Matrix converter input varying q<br />
66