Version: 2Q05 Standard ICA<br />
07/06/05<br />
Attachment 4-Central Office<br />
Page 32<br />
breaker ampere, per month basis, pursuant to the rates specified in Exhibit B. The<br />
AC power rates include recovery for the provision of commercial and standby AC<br />
power. When obtaining power from a BellSouth service panel, protection devices<br />
and power cables must be engineered (sized) and installed by OTI’s BellSouth<br />
Certified Supplier, with the exception that BellSouth shall engineer and install<br />
protection devices and power cables for Adjacent Collocation. OTI’s BellSouth<br />
Certified Supplier must provide a copy of the engineering power specifications<br />
prior to the Commencement Date. AC power voltage and phase ratings shall be<br />
determined on a per location basis. At OTI’s option, OTI may arrange for AC<br />
power in an adjacent collocation arrangement from a retail provider of electrical<br />
power.<br />
8.7.8 OTI shall contract with a BellSouth Certified Supplier to perform the installation<br />
and removal of dedicated power cable support structure within OTI’s arrangement<br />
and terminations of cable within the Collocation Space.<br />
8.7.9 Fused Amp Billing. In all states, except as noted in Section 8.7.1 above for<br />
Florida, BellSouth shall make available –48V DC power on a per fused amp, per<br />
month basis, pursuant to the following formula:<br />
For power provisioned from a BDFB. The number of fused amps requested by<br />
OTI on its application should reflect a multiplier of one point five (1.5) to<br />
convert its requested amps to fused amps, with a minimum of ten (10) fused<br />
amps required. The number of fused amps requested by OTI on its collocation<br />
application will be multiplied by the DC power fused amp rate set forth in<br />
Exhibit B.<br />
For existing power configurations that are provisioned from BellSouth’s main<br />
power board. The number of fused amps made available at the main power<br />
board, in increments of two hundred twenty-five (225) amps/main power board<br />
circuit, will be multiplied by the DC power fused amp rate set forth in Exhibit<br />
B. In Florida, the number of fused amps requested by OTI on its collocation<br />
application will be multiplied by the DC power fused amp rate set forth in<br />
Exhibit B<br />
8.7.10 Florida Power Usage Option<br />
8.7.10.1 In Florida only, OTI may request that –48 DC power provisioned by BellSouth to<br />
OTI’s Collocation Space be assessed per amp, per month based upon amps used,<br />
pursuant to the rates set forth in Exhibit B. Monthly recurring power charges will<br />
be assessed on the Space Acceptance Date or Space Ready Date, whichever is<br />
appropriate, pursuant to Section 8.3 above. If OTI desires to convert existing<br />
physical collocation arrangements to the Florida Power Usage Option (hereinafter<br />
“FL Option”), then the monthly recurring power charges that are applicable to the<br />
FL Option, contained in Exhibit B, will be assessed on the Space Ready Date<br />
associated with the Subsequent Application submitted by OTI to convert an<br />
CCCS 163 of 261