Version: 2Q05 Standard ICA - New<br />
07/06/05<br />
Attachment 2<br />
Page 10<br />
2.1.4.11.6.1 If OTI fails to submit the spreadsheet(s) specified in Section 2.1.4.11.6 above for<br />
all of its Subsequent Embedded Base within forty (40) days after the date of<br />
BellSouth’s CNL identifying the Subsequent Wire Center List, BellSouth will<br />
identify OTI's remaining Subsequent Embedded Base, if any, and will transition<br />
such circuits to the equivalent tariffed BellSouth service(s). Those circuits<br />
identified and transitioned by BellSouth shall be subject to the applicable<br />
disconnect charges as set forth in this Agreement and the full nonrecurring charges<br />
for installation of the equivalent tariffed BellSouth service as set forth in<br />
BellSouth's tariffs.<br />
2.1.4.11.6.2 For Subsequent Embedded Base circuits converted pursuant to Section 2.1.4.11.6<br />
above or transitioned pursuant to Section 2.1.4.11.6.1 above, the applicable<br />
recurring tariff charges shall apply as of the earlier of the date each circuit is<br />
converted or transitioned, as applicable, or the first day after the end of the<br />
Subsequent Transition Period.<br />
2.1.5 Where facilities are available, BellSouth will install Loops in compliance with<br />
BellSouth’s Products and Services Interval Guide available at BellSouth’s<br />
Interconnection Web site. For orders of fifteen (15) or more Loops, the<br />
installation and any applicable Order Coordination (OC) as described below will be<br />
handled on a project basis, and the intervals will be set by the BellSouth project<br />
manager for that order. When Loops require a Service Inquiry (SI) prior to<br />
issuing the order to determine if facilities are available, the interval for the SI<br />
process is separate from the installation interval.<br />
2.1.6 The Loop shall be provided to OTI in accordance with BellSouth’s TR73600<br />
Unbundled Local Loop Technical Specification and applicable industry standard<br />
technical references.<br />
2.1.7 BellSouth will only provision, maintain and repair the Loops to the standards that<br />
are consistent with the type of Loop ordered.<br />
2.1.7.1 When a BellSouth technician is required to be dispatched to provision the Loop,<br />
BellSouth will tag the Loop with the Circuit ID number and the name of the<br />
ordering CLEC. When a dispatch is not required to provision the Loop, BellSouth<br />
will tag the Loop on the next required visit to the End User’s location. If OTI<br />
wants to ensure the Loop is tagged during the provisioning process for Loops that<br />
may not require a dispatch (e.g., UVL-SL1, UVL-SL2, and UCL-ND), OTI may<br />
order Loop Tagging. Rates for Loop Tagging are as set forth in Exhibit A.<br />
2.1.7.2 For voice grade Loop orders (or orders for Loops intended to provide voice grade<br />
services), OTI shall have dial-tone available for that Loop forty-eight (48) hours<br />
prior to the Loop order completion due date.<br />
2.1.8 OC and Order Coordination-Time Specific (OC-TS)<br />
CCCS 53 of 261