2.7.4 Technical Requirements<br />
Version: 2Q05 Standard ICA - New<br />
07/06/05<br />
Attachment 2<br />
Page 21<br />
2.7.4.1 The NID shall provide an accessible point of interconnection and shall maintain a<br />
connection to ground.<br />
2.7.4.2 If an existing NID is accessed, it shall be capable of transferring electrical analog<br />
or digital signals between the End User’s customer premises and the distribution<br />
media and/or cross-connect to OTI’s NID.<br />
2.7.4.3 Existing BellSouth NIDs will be operational and provided in “as is” condition.<br />
OTI may request BellSouth to do additional work to the NID on a time and<br />
material basis. When OTI deploys its own local loops in a multiple-line<br />
termination device, OTI shall specify the quantity of NID connections that it<br />
requires within such device.<br />
2.8 Subloop Elements.<br />
2.8.1 Where facilities permit, BellSouth shall offer access to its Unbundled Subloop<br />
(USL) elements as specified herein.<br />
2.8.2 Unbundled Subloop Distribution (USLD)<br />
2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from<br />
an End User’s point of demarcation to a BellSouth cross-connect device. The<br />
BellSouth cross-connect device may be located within a remote terminal (RT) or a<br />
stand-alone cross-box in the field or in the equipment room of a building. The<br />
USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire<br />
facility. BellSouth will make available the following subloop distribution offerings<br />
where facilities exist:<br />
USLD – Voice Grade (USLD-VG)<br />
Unbundled Copper Subloop (UCSL)<br />
USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))<br />
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and<br />
including the point of demarcation at the End User’s premises and may have load<br />
coils.<br />
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length<br />
provided from the cross-box in the field up to and including the End User’s point<br />
of demarcation. If available, this facility will not have any intervening equipment<br />
such as load coils between the End User and the cross-box.<br />
2.8.2.3.1 If OTI requests a UCSL and it is not available, OTI may request the copper<br />
Subloop facility be modified pursuant to the ULM process to remove load coils<br />
CCCS 64 of 261