EOI the keyword used to terminate input.<br />

If the spray model is selected as the ESF in an engineered system, certain combinations <strong>of</strong><br />

components must be specified. One combination consists <strong>of</strong> SOURCE and SPRAY, with<br />

OVERFLOW optional. The other combination consists <strong>of</strong> TANK, PUMP, HEX, and SPRAY, with<br />

OVERFLOW optional. An example <strong>of</strong> the input <strong>for</strong> the latter combination is given below.<br />

ENGINEER SAMPLE1 4220.0<br />

EOI<br />

SPRAY<br />

EOI<br />

TANK<br />

PUMP<br />

HEx<br />

SPPC12=6000.0<br />

SPSTPR=<strong>2.0</strong>e5<br />

5000.0<br />

280.0<br />

200.0<br />

200.0<br />

USER=50.<br />

&& engineered system has four components<br />

&& outlet to and recirculation from cell 2<br />

&& elevation difference= O<br />

&& elemental iodine partition coefficient<br />

&& pressure initiation at <strong>2.0</strong> x 105 Pa<br />

&& mass <strong>of</strong> water available in the tank<br />

&& source water temperature<br />

&& water flow rate from the tank<br />

&& flow rate <strong>for</strong> recirculation<br />

&& user-specified temperature drop <strong>of</strong> 50 K<br />

14.3.3.5 Heat Excharw er. Five liquid-liquid heat exchanger options are available. The keyword<br />

SHELL invokes the appropriate heat transfer correlations <strong>for</strong> a shell and tube, single-pass heat<br />

exchanger. CROSS denotes a cross-flow heat exchanger; COUNTER, a counterflow type;<br />

PAIU4LLEL, a parallel flow type; and USER, a user-specified constant temperature drop across the<br />

hot leg. The heat exchanger component is used only with the spray ESF.<br />

***** ***** ***** ***** ***** ************************************************<br />

HEX {otype hxticl hxclmd hxarea hxcoef or USER hxdelt}<br />

***** ***** ***** ***** ***** ************************************************<br />

HEx the keyword to initiate the specification <strong>of</strong> the heat exchanger component.<br />

Otype a heat exchanger type keyword. Either SHELL, CROSS, COUNTER, or<br />

PARALLEL must be specified.<br />

hxticl the cold side inlet temperature. (K)<br />

hxclmd the cooling water flow rate through the cold side. (kg/s)<br />

Rev O 14 153 6/30/97