I<br />

Validation<br />

Type/Basis<br />

Separate<br />

effectsiMIT<br />

single tube<br />

experiments<br />

Separate<br />

effects/UCB<br />

single tube<br />

experiments<br />

Separate<br />

effects/MIT<br />

single tube<br />

experiments<br />

Separate<br />

effects/Kim<br />

experiment<br />

Separate<br />

effects/Piss<br />

experiments<br />

Separate<br />

effects/<br />

U. Wise.<br />

experiments<br />

Table C-5 Validation Matrix <strong>for</strong> Heat and Mass Transfer Modeling (Non-<strong>CONTAIN</strong> Comparisons) (Continued)<br />

Reference<br />

Transfer Type/<br />

Regime<br />

Has96a Condensation)<br />

turbulent <strong>for</strong>ced<br />

Has96a Condensation/<br />

Iturbulent<br />

<strong>for</strong>ced<br />

Has96b Condensation/<br />

turbulent <strong>for</strong>ced<br />

Amb95 Evaporation/<br />

turbulent <strong>for</strong>ced (O<br />

to 10In/s)<br />

Huh93 Condensation/<br />

turbulent <strong>for</strong>ced (1<br />

to 3 rids)<br />

Gas<br />

Mixture<br />

Steam/air HMTA with film<br />

equations<br />

1<br />

Model Geometty Parameter<br />

h (W/m2-K), or<br />

Other<br />

Vertical tube,<br />

inside<br />

condensation<br />

Steam/N2 Vertical tube,<br />

inside<br />

condensation<br />

Steam/air/<br />

He<br />

Steam/air<br />

(air mass<br />

fraction =<br />

0.4)<br />

Water/air<br />

“Refers to the heat and mass transfer analogy discussed in Section C.3.2<br />

HMTA with film<br />

equations<br />

HMTA with film<br />

equations<br />

Vertical tube,<br />

inside<br />

condensation<br />

Horizontal<br />

plate<br />

h(2000-8000)<br />

(local)<br />

h(O-7000)<br />

(local)<br />

Model<br />

Ranking<br />

HMTA Vertical duct Ns~(90-400) M-H<br />

Stearnlair HMTA Horizontalto<br />

verticalduct<br />

Comments<br />

L-M The heat transfer<br />

coefficients were overpredicted<br />

(local analysis)<br />

L The heat transfer<br />

coefficients were overpredicted<br />

(local analysis)<br />

h(500-4500) H Results <strong>of</strong> local analysis<br />

were compared.<br />

Total heat flux H Laminar condensate flow<br />

without waves was presen<br />

h(100-1000) M-H<br />

AP600 PCS wall evapora<br />

tion was studied within a<br />

thin film approximation.<br />

Condensation on inclined<br />

ceilings was studied.<br />

Rev. O C-27 6/30