■ Options<br />

■ More information<br />

Project-specific cabinets<br />

Siemens AG<br />

Apart from the standardized cabinets, we manufacture cabinets A&D SE S2<br />

for specific projects or customer requirements:<br />

76187 Karlsruhe, Germany<br />

• Cabinets or different sizes and designs,<br />

Tel.: +49 721 595-3776<br />

• small wall-mounted housings for distributed construction or Fax: +49 721 595-4711<br />

• outdoor units with air conditioning.<br />

All are offered with the option of Ex-zone versions and non-standard<br />

degrees of protection such as NEMA 4x or IP66.<br />

E-mail: addon_s2@siemens.com<br />

Cabinet construction<br />

Cabinet construction for SIMATIC <strong>PCS</strong> 7<br />

■ Selection and Ordering Data Order No.<br />

ET 200M peripheral device 6DL2802-<br />

7 7 7 7 7<br />

Installation of the I/O modules<br />

• without installation of the I/O modules 0<br />

• without installation of the I/O modules, prepared with dividing segment and plate in cable duct for Ex(i) design 1<br />

• Installation of 4 I/O modules, connect L+ and M- supply, test modules and set parameters 2<br />

• Installation of 8 I/O modules, connect L+ and M- supply, test modules and set parameters 3<br />

• Installation of 4 I/O modules for Ex(i), connect L+ and M- supply, test modules and set parameters, cable<br />

guide for L+ I/O-module supply, dividing segment between non-hazardous and hazardous areas, dividing<br />

plate in cable duct, cable duct marked in blue<br />

4<br />

• Installation of 8 I/O modules for Ex(i), connect L+ and M- supply, test modules and set parameters, cable<br />

guide for L+ I/O-module supply, dividing segment between non-hazardous and hazardous areas, dividing<br />

plate in cable duct, cable duct marked in blue<br />

Test<br />

5<br />

• without test I/O-functions 0<br />

• Function test inputs/outputs for 4 modules 1<br />

• Function test inputs/outputs for 8 modules<br />

DP/PA coupler<br />

2<br />

• Installation, wiring and bus connection of up to<br />

4 DP/PA couplers on 19" DIN rails without individual<br />

fusing of the I/O modules<br />

Order DP-bus connectors separately according to<br />

number of couplers.<br />

6DL2 803-1AA00<br />

• Installation, wiring and bus connection of up to<br />

4 DP/PA couplers on 19" DIN rails with individual fusing<br />

of the I/O modules<br />

Order DP-bus connectors separately according to<br />

number of couplers.<br />

DP/PA Link<br />

Installation, wiring and bus connection of IM 157 and<br />

up to 4 DP/PA couplers on 19" DIN rails without individual<br />

fusing of the I/O modules<br />

Order bus modules separately for hot swapping function.<br />

Installation, wiring and bus connection of IM 157 and<br />

up to 4 DP/PA couplers on 19" DIN rails with individual<br />

fusing of the I/O modules<br />

Order bus modules separately for hot swapping function.<br />

6DL2 803-1AA10<br />

6DL2 803-1BA00<br />

6DL2 803-1BA10<br />

Siemens <strong>ST</strong> <strong>PCS</strong> <strong>7.1</strong> · <strong>September</strong> <strong>2005</strong><br />