Eectch98-Part1.fm<br />

OP-CODE 8096 8061/5 DESCRIPTI<strong>ON</strong> DIFFERENCE<br />

B4-B7 ADDCB ADCB add bytes with carry rename<br />

B8-BB SUBCB SBBB subtract bytes with borrow rename<br />

BC-BF LDBSE LDSBW load integer with byte, sign extended rename<br />

C0/2/3 ST STW store word rename<br />

C1 nu<br />

C4/6/7 STB STB store byte same<br />

C5 nu<br />

C8-CB PUSH PUSHW push word rename<br />

CC/E/F POP POPW pop word rename<br />

CD nu<br />

D0 JNST JNST jump if sticky bit is clear same<br />

D1 JNH JLEU jump if unsigned not higher rename<br />

D2 JGT JGT jump if signed greater than same<br />

D3 JNC JNC jump if carry flag is clear same<br />

D4 JNVT JNVT jump if overflow trap is clear same<br />

D5 JNV JNV jump if overflow flag is clear same<br />

D6 JGE JGE jump if signed greater than or equal same<br />

D7 JNE JNE jump if not equal same<br />

D8 JST JST jump sticky bit is set same<br />

D9 JH JGTU jump if unsigned higher rename<br />

DA JLE JLE jump if signed less than or equal same<br />

DB JC JC jump if carry flag is set same<br />

DC JVT JVT jump if overflow trap is set same<br />

DD JV JV jump if overflow flag is set same<br />

DE JLT JLT jump if signed less than same<br />

DF JE JE jump if equal same<br />

E0 DJNZ DJNZ decrement and jump if not zero same<br />

E1 nu<br />

E2 nu<br />

E3 BR branch indirect not in 8061/5<br />

E4 nu<br />

E5 nu<br />

E6 nu<br />

E7 LJMP JUMP long jump rename<br />

E8 nu<br />

E9 nu<br />

EA nu<br />

EB nu<br />

EC nu<br />

ED nu<br />

EE nu<br />

EF LCALL CALL long call rename<br />

F0 RET RET return from subroutine same<br />

F1 ----- RETEI/RETI retei-8065 reti - 8061 not in 8096<br />

F2 PUSHF PUSHP push flags rename<br />

F3 POPF POPP pop flags rename<br />

F4 BANK 0 8065 only - not in 8096<br />

F5 BANK 1 8065 only - not in 8096<br />

F6 BANK 2 8065 only - not in 8096<br />

F7 TRAP INT software trap (internal use only, not in assembler)<br />

F8 CLRC CLC clear carry flag same<br />

F9 SETC STC set carry flag rename<br />

FA DI DI disable interrupt same<br />

FB EI EI enable interrupt same<br />

Table 10: 8096-8061 Op-Codes<br />