values. Divide them by 4 to convert to decimal.<br />
RPM<br />
L<br />
O<br />
A<br />
D<br />
%<br />
500 700 900 1100 1300 1500 2000 2500 3000 4000<br />
75 9.25 9.25 13.00 13.00 15.50 18.25 23.50 23.50 23.50 23.50<br />
60 9.25 11.50 13.00 13.00 15.50 18.25 23.50 23.50 23.50 23.50<br />
50 9.00 10.25 11.50 12.75 15.00 19.75 25.50 25.50 25.50 25.50<br />
40 16.00 16.00 16.00 16.00 18.50 24.25 31.25 31.25 31.25 31.25<br />
30 23.00 24.25 23.00 27.50 35.75 37.00 38.00 38.00 38.00 38.00<br />
23 25.00 26.00 30.50 38.75 40.25 42.00 43.75 43.75 43.75 43.75<br />
15 28.00 28.00 28.00 31.25 33.25 34.25 34.25 34.25 34.25 34.25<br />
05 28.00 28.00 28.00 27.25 29.00 30.00 30.00 30.00 30.00 30.00<br />
Table 28: Limp Mode Spark Table [Deg BTDC]<br />
Eectch98-Part2.fm<br />
The Limp Mode Spark Table [Deg BTDC] Table lives at 7614 (30228 decimal) as unsigned byte<br />
values that must be divided by 4 to convert to their real values.<br />
0 0 0 0 2 2 2 2<br />
Table 29: Injector Output Port Table<br />
The Injector Output Port Table lives at (29105 decimal) for the A9L as unsigned bytes.<br />
Raw Load<br />
Table Row<br />
Pointer<br />
0 0<br />
0.04998779296875 0<br />
0.100006103515625 1<br />
0.600006103515625 6<br />
0.75 7<br />
1.99996948242188 7<br />
Table 30: Load Scaling<br />
The Load Scaling Function parameters for the A9L are located at 6C62. The table is<br />
24 bytes in size, organized in a 2-byte by 2-byte unsigned, interleaved format. The<br />
“X” values (Load) must be divided by 32768 to convert them and the “Y” values (Row<br />
<strong>EEC</strong>-<strong>IV</strong> Technical Notes: Software 31 last edited: 9/29/98