22.10.2013 Views

TECHNICAL NOTES ON THE EEC-IV MCU - Auto diagnostics

TECHNICAL NOTES ON THE EEC-IV MCU - Auto diagnostics

TECHNICAL NOTES ON THE EEC-IV MCU - Auto diagnostics

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Scalar A9L<br />

Idle Speed Neutral<br />

Idle Speed Drive<br />

CID<br />

Number HEGO Sensors<br />

WOT TPS value<br />

EGR Multiplier<br />

EGR Type<br />

PIP Filter * 7C16<br />

Half Fuel Rev Limit <strong>ON</strong> 7A82<br />

Half Fuel Rev Limit OFF 7A84<br />

Speed Limit A -- <strong>ON</strong> * 7A86<br />

Speed Limit A -- OFF * 7A87<br />

Speed Limit B-- <strong>ON</strong> * 7A88<br />

Speed Limit B-- OFF * 7A89<br />

Maximum Spark Retard<br />

Cooling Fan ECT HI/LO/Hysteresis<br />

Intake Manifold Volume<br />

Thermactor Presence<br />

Table 18: <strong>EEC</strong> Scalars<br />

Scalar Examples<br />

Eectch98-Part2.fm<br />

Scalars for ‘86-’93 Mustang from Calibrator Demo ‘94-5 Mustang Scalars from Calibrator Demo<br />

Injector Size (lbs/hr) 19.64 High Injector Slope (lb/hr) 19.641<br />

Injector Slope 0.0072494 Low Injector Slope (lb/hr) 28.8<br />

Global Accel Pump Multiplier 0.40 Injector Breakpoint 1.0014e-005<br />

Gobal Open Loop Fuel Multiplier 1.00 Min Injector Pulsewidth 0.0014<br />

Global Injector Delay (Crank Deg) 0 ACT Minimum for Adaptive Control (Deg F) -20<br />

Closed Throttle Spark Adder (Deg BTDC) 0 ACT Maximum for Adaptive Control (Deg F) 160<br />

Part Throttle Spark Adder (Deg BTDC) 0 Global Spark Adder 0<br />

WOT Spark Adder (DEG BTDC) 0 Max Degrees of Spark Retard -15<br />

Tip-in Spark Retard (Deg BTDC) 0 Minimum Tip-in Spark (Deg) 5<br />

Maximum Lo-Speed Dwell (OFF Time in mS) 0.50000 Gobal Open Loop Fuel Multiplier 1.00<br />

Maximum Hi-Speed Dwell (OFF Time in mS) 0.20000 WOT TP Breakpoint (V) 3.0518<br />

ACT Minimum for Adaptive Control (Deg F) 100 ECT to Turn <strong>ON</strong> HS Cooling fan 228<br />

ACT Maximum for Adaptive Control (Deg F) 200 ECT to Turn OFF HS Cooling fan 220<br />

Minimum ECT for Deceleration Fuel Shutoff (Deg F) 140 ECT to Turn OFF LS Cooling fan 204<br />

Minimum RPM for Deceleration Fuel Shutoff 149.75 ECT to Turn <strong>ON</strong> LS Cooling fan 208<br />

Minimum Load (MAP) for Closed Loop .0050049 Min ECT to Allow Decel Fuel Cut-off 140<br />

Hi-load Timeout to Open Loop (Seconds) 2 Intake Manifold Volume 4<br />

Idle RPM in Neutral 672 Open Loop Idle Multiplier 1<br />

Idle RPM in Drive 672 CID 301.04<br />

CID 301.04 EGR Multiplier 1<br />

Number HEGO Sensors 2 EGR Type (2=None) 0<br />

WOT TPS Breakpoint (A/D Counts) 555 Thermactor Present (0/1 = NO/YES) 1<br />

EGR Multiplier 1 Enable Stage 1 Speed Limiter 10000<br />

PIP Filter (CPU Cycles/Crank Rev) 961 Disable Stage 1 Speed Limiter 10000<br />

Turn <strong>ON</strong> Half Fuel Rev Limit 6100 Enable Stage 2 Speed Limiter 10000<br />

Turn OFF Half Fuel Rev Limit 6100<br />

Maximum RPM (No Fuel) 6250<br />

Turn <strong>ON</strong> 1st Speed Limiter (MPH) 127.5<br />

Turn OFF 1st Speed Limiter (MPH) 127.5<br />

Turn <strong>ON</strong> 2nd Speed Limiter (MPH) 127.5<br />

Turn OFF 2nd Speed Limiter (MPH) 127.5<br />

Table 19: Example Scalars from Calibrator Demo<br />

<strong>EEC</strong>-<strong>IV</strong> Technical Notes: Software 27 last edited: 9/29/98

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!