26.01.2014 Views

bs sponge private limited - India Environment Portal

bs sponge private limited - India Environment Portal

bs sponge private limited - India Environment Portal

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

B.S. SPONGE PRIVATE LIMITED<br />

Village: Taraimal, Tehsil: Gharghoda, District: Raigarh, (C.G.)<br />

REIA Report for the Proposed Mini Integrated Steel Plant<br />

Chapter – 10<br />

‣ Energy meters will be installed for all the pollution control systems.<br />

‣ Rain water harvesting pits are being constructed as per the guidelines issued by<br />

CGWB.<br />

Recommendations<br />

a) The proposed air pollution control equipment will be installed prior to commissioning<br />

the expansion plant.<br />

b) Continuous monitoring system for particulate matter in the stacks will be provided.<br />

c) Pressure drop measuring system will be installed to measure the pressure drop across<br />

the bag filters.<br />

d) All the internal roads shall be asphalted to reduce the fugitive dust due to truck<br />

movement.<br />

10.2.2 WATER POLLUTION MANAGEMENT<br />

10.2.2.1 SMS, ROLLING MILL & FERRO ALLOYS<br />

Closed circuit cooling system will be provided in DRI plant, cooling of Billets, TMT bars &<br />

Ferro alloys. Hence there will not be any waste water generation from process and cooling in<br />

the steel plant.<br />

10.2.2.2 POWER PLANT<br />

Total waste water generation from the proposed 12 MW WHRB based Power plant and 36<br />

MW FBC based power plant is 367 cum/day (including sanitary waste water). The boiler<br />

blowdown & DM Plant regeneration water will be treated in a neutralization tank and after<br />

treatment it will be mixed with CT Blow down and treated service water. The treated effluent<br />

will be stored in a Central Monitoring Basin (CMB). The treated effluent will be used for<br />

onland for irrigation within the premises after ensuring compliance with CPCB/CECB<br />

standards.<br />

Total effluent generated (excluding sanitary waste water)<br />

Effluent to be used for Ash Conditioning & dust suppression<br />

Effluent to be used for greenbelt development<br />

: 367 cum/day<br />

: 75 cum/day<br />

: 292 cum/day<br />

Zero effluent discharge is being maintained in the existing plant and will be continued in the<br />

expansion also.<br />

PIONEER ENVIRO 10- 14 <strong>Environment</strong>al Impact Assessment Report<br />

Laboratories & Consultants Pvt. Ltd.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!