B.S. SPONGE PRIVATE LIMITED<br />

Village: Taraimal, Tehsil: Gharghoda, District: Raigarh, (C.G.)<br />

REIA Report for the Proposed Mini Integrated Steel Plant<br />

Chapter – 4<br />

Hence a stack of 72 m height will be provided to the AFBC boiler stack for effective<br />

dispersion of emissions into the atmosphere.<br />

4.1.3.3 STACK HEIGHT CALCULATION (ROLLING MILL)<br />

FO Consumption per Rolling mill : 11.9 TPD<br />

Sulphur content in FO : 4.5 % (by mass, Max.)<br />

SO2 emission : 11.9 X 1000 X 4.5 X 2/24x100<br />

: 44.625 Kg/hr<br />

Stack Height H, : 14 (Q) 0.3<br />

: 14 (44.625) 0.3 = 43.75 m or say 45 m<br />

Hence stack of 45 m height will be provided for effective dispersion of emissions into<br />

the atmosphere.<br />

Sources of Air Emissions :<br />

The main sources of fugitive emissions are raw material unloading, raw material handling,<br />

crushers of coal, material transfer points, storage bins, etc. Dust generated from raw<br />

material unloading areas is controlled by providing dust suppression system. In other<br />

areas specified above dust extraction system with bag filters will be provided to control<br />

the particulate emission.<br />

The waste flue gases from kilns will be allowed to pass through a Waste Heat Recovery<br />

Boiler (WHRB) and then after heat recovery the gases will pass through an Electrostatic<br />

Precipitator (ESP) to bring down the particulate matter to less than 50 mg/Nm 3 and will be<br />

let out into the atmosphere through two nos. of combined stacks (each with twin flues)<br />

each of 60 m height for effective dispersion of emissions into the atmosphere.<br />

Fumes will be evacuated directly from both the Induction Furnaces through a swiveling<br />

type of hoods with an air-cooled ducting. The duct carrying fumes from the Induction<br />

furnace and CCM will join a mixing chamber from where the gases will be led to the Bag<br />

House by means of an ID fan. Clean gases having less than 50 mg/Nm 3 of particulates will<br />

be let out through two common stacks (with two flues) each of 30 m height.<br />

In Reheating Furnace the fuel proposed to be used is FO. Stack of 45 m height will be<br />

provided for effective dispersion of SO2 emissions into the atmosphere.<br />

The primary & secondary fugitive emissions from submerged Electric arc furnaces from<br />

Ferro alloys unit will be treated in Fume extraction & cleaning system comprising of<br />

PIONEER ENVIRO 4 - 8 <strong>Environment</strong>al Impact Assessment Report<br />

Laboratories & Consultants Pvt. Ltd.