B.S. SPONGE PRIVATE LIMITED<br />

Village: Taraimal, Tehsil: Gharghoda, District: Raigarh, (C.G.)<br />

REIA Report for the Proposed Mini Integrated Steel Plant<br />

Chapter – 4<br />

suction hoods, bag filters etc . The outlet dust emissions in the exhaust gases will be less<br />

than 50 mg/Nm 3 . The treated gases will be discharged into the atmosphere through stacks<br />

of 30 m height (2 nos).<br />

The waste flue gases from AFBC boiler will pass through an Electrostatic Precipitator<br />

(ESP) to bring down the particulate matter to less than 50 mg/Nm 3 and will be let out into<br />

the atmosphere through a stack of 72 m height for effective dispersion of emissions into<br />

the atmosphere.<br />

The predicted max. incremental rise in SPM concentrations (24 hourly) will be 0. 6µg/m 3 at<br />

a distance of 1100 m from the origin stack in the down wind direction over the baseline<br />

concentrations.<br />

The predicted max. incremental rise in SO 2 concentrations (24 hourly) will be 8.9 µg/m 3 at<br />

a distance of 1100 m from the origin stack in the down wind direction over the baseline<br />

concentrations.<br />

The predicted max. incremental rise in NOx concentrations (24 hourly) will be 4.7 µg/m 3<br />

at a distance of 1100 m from the origin stack in the down wind direction over the baseline<br />

concentrations.<br />

The net resultant concentrations (Maximum baseline conc. + predicted incremental rise in<br />

conc.) of SPM, SO 2 and NO X are shown in Table No. 4.1.4. The net resultant<br />

concentrations of SPM, SO 2 and NO X are well within the National Ambient Air Quality<br />

Standards (NAAQS) when the plant commences the operation. Hence there will not be<br />

any adverse impact on air environment due to the proposed expansion project.<br />

S. No. Stack attached to<br />

1.<br />

2.<br />

Kilns(2 x 100 TPD)<br />

with WHRB<br />

(Stack # 1 with<br />

twin flues)<br />

Kilns(2 x 100 TPD)<br />

with WHRB<br />

(Stack # 2 with<br />

twin flues)<br />

Dia<br />

(m)<br />

1.16<br />

per<br />

flue<br />

1.16<br />

per<br />

flue<br />

TABLE 4.1.3<br />

STACK EMISSIONS<br />

Height<br />

(m)<br />

60<br />

(Combin<br />

ed stack<br />

with<br />

twin<br />

flues)<br />

60<br />

(Combin<br />

ed stack<br />

with<br />

twin<br />

flues)<br />

Temp. of<br />

flue gas<br />

( 0 C)<br />

Velocity of<br />

flue gas<br />

(m/sec)<br />

180 16<br />

180 16<br />

SPM<br />

(g/s)<br />

0.6<br />

(< 50<br />

mg/Nm 3 )<br />

per flue<br />

0.6<br />

(< 50<br />

mg/Nm 3 )<br />

per flue<br />

SO 2<br />

(g/s)<br />

15.1<br />

per<br />

flue<br />

15.1<br />

per<br />

flue<br />

NOx<br />

(g/s)<br />

6.0<br />

per<br />

flue<br />

6.0<br />

per<br />

flue<br />