Part III: Flare Reduction Project Family - IPIECA
Part III: Flare Reduction Project Family - IPIECA
Part III: Flare Reduction Project Family - IPIECA
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Section 7. <strong>Flare</strong> <strong>Reduction</strong> <strong>Project</strong> <strong>Family</strong><br />
EXHIBIT 7.2:<br />
<strong>Flare</strong> Gas Recovery for Re-injection and Utilization, continued<br />
Indirect emissions (IND 2 ):<br />
There are no indirect emissions associated with either the baseline or the project scenario.<br />
PROJECT EMISSIONS = CMB 2 + VENT 2 + FUG 2 + IND 2<br />
= 475,200+224+ 1,025 +0<br />
= 476,449 tonnes CO 2 e per year<br />
EMISSION REDUCTIONS = Baseline Emissions – <strong>Project</strong> Emissions<br />
= (5,749,920 – 476,449 ) tonnes CO 2 e per year<br />
= 5,273,471 tonnes CO 2 e per year<br />
Monitoring<br />
Monitoring for this project example would include the following:<br />
• The composition and quantity of unprocessed associated gas delivered to the OGPP and<br />
of the processed high-, medium-, and low-pressure gas streams produced by the OGPP.<br />
• Quantities of processed gas sent to the IPP and the oilfield re-injection area.<br />
• The types and quantities of any additional fuels consumed in the processing and transport<br />
of the recovered gas, if any.<br />
• The CH 4 content and operating time of equipment and processes subject to venting and<br />
fugitive emissions, and associated with the processing and transport of the recovered gas.<br />
October 2009 41