Page 37<br />
Dual-Tap <strong>TM</strong>/<strong>RM</strong>-<strong>2040GE</strong> AccuPiXEL Series Camera-Control Software<br />
FIGURE 34. To use Programmable shutter speed, select Programmable.<br />
7.1.1 (b) Expo (lines)<br />
The Expo (lines) selection of the Exposure Control frame determines how long the shutter remains<br />
open, since a certain amount of time is allotted to expose each line. A minimum of one line of pixels<br />
must be exposed. The maximum number of lines is 2048. Enter the number of lines desired either by<br />
clicking on the arrows in the interface, or by inputting a number directly into the box beside the “Expo<br />
(lines)” box.<br />
7.1.1 (c) <strong>Scan</strong> Area<br />
Changing the scan area affects the image resolution. If desired, the size of the scan area can be selected<br />
from the drop-down list box. When the <strong>Scan</strong> Area setting is used to designate the number of lines, the<br />
rest of the Exposure Control frame is disabled. For more information on programmable scans see<br />
“Programmable <strong>Scan</strong> Area” on page 53<br />
FIGURE 35. The <strong>Scan</strong> Area drop down box.<br />
<strong>Scan</strong> area can vary from a, b, c, or d, to Programmable, various Zoom levels, and more.<br />
GUI Features