Stability measuring instruments<br />

Oxidation stability of fats and oils<br />

743 Rancimat<br />

A new era in the determination of the oxidation<br />

stability of natural fats and oils<br />

The 743 Rancimat as a modern, PC-controlled instrument<br />

allows the comfortable determination of oxidation<br />

stability. Disposable reaction vials reduce the<br />

amount of cleaning of the accessories to the absolute<br />

minimum. This saves both time and money. In addition,<br />

the accuracy and reproducibility are significantly<br />

improved. With the help of the certified temperature<br />

sensor in the GLP set it is now possible to adjust the<br />

temperature very precisely and reproducibly, which<br />

improves the comparability of the results even further.<br />

The software of the third Rancimat generation with<br />

automatic data recording and evaluation as well as a<br />

measurement database allows the comfortable management<br />

of large amounts of data.<br />

Oxidation stability of natural fats and oils in the<br />

food industry<br />

The determination of the oxidation stability of oils and<br />

fats is the classical application for the 743 Rancimat.<br />

The so-called induction time thus determined characterizes<br />

the resistance of oils and fats to oxidation.<br />

Instead of induction time, the term oil stability index<br />

(OSI) is frequently used.<br />

Ordering information<br />

2.743.0014 743 Rancimat for oils and fats (230 V)<br />

2.743.0015 743 Rancimat for oils and fats (115 V)<br />

Options<br />

6.5616.000 GLP Test Set for 743 Rancimat and 763<br />

PVC Thermomat<br />

The Rancimat method is an automated version of<br />

the previously used and extremely complicated AOM<br />

method (Active Oxygen Method). The Rancimat<br />

method is used as a standard test in the food industry<br />

for quality control during the manufacture of fats<br />

and oils or for checking incoming goods in processing<br />

industries. In addition to vegetable oils and fats, it is<br />

also possible to check the oxidation stability of animal<br />

fats such as hog fat, tallow or fish oil. Foodstuffs may<br />

contain added antioxidants in order to slow down the<br />

oxidative decomposition of the oils and fats. By using<br />

the 743 Rancimat it is possible to characterize the<br />

effectiveness of antioxidants.<br />

Standards<br />

• AOCS Cd 12b-92 (AOCS – American Oil Chemists'<br />

Society): Sampling and analysis of commercial fats<br />

and oils: Oil Stability Index<br />

• ISO 6886: Animal and vegetable fats and oils<br />

– Determination of oxidative stability (accelerated<br />

oxidation test)<br />

• 2.4.28.2-93: Fat stability test on Autoxidation. CDM,<br />

Japan<br />

Oxidation stability of foodstuffs and cosmetics<br />

The 743 Rancimat can also be used for the determination<br />

of the oxidation stability of foods containing fats.<br />

In addition to foodstuffs, the oxidation stability of<br />

cosmetics or cosmetic additives containing fats can be<br />

determined with the 743 Rancimat.<br />

743 Rancimat with laptop PC<br />

— St