Professional IC Systems<br />

«ProfIC 10 – Anion» – Professional IC system<br />

with inline sample preconcentration, matrix<br />

elimination and matrix neutralization<br />

Professional IC system for the determination of anions<br />

in difficult matrices. «ProfIC 10» with Metrohm inline<br />

sample preconcentration, matrix neutralization and<br />

matrix elimination allows chromatography unaffected<br />

by matrix influences and guarantees that the analytical<br />

column has a long lifetime.<br />

A small volume of the sample is transferred fully automatically<br />

to the preconcentration column. On its way it<br />

passes through the sample preparation module, where<br />

complete cation exchange takes place. This means<br />

that it is possible to neutralize both acids and bases.<br />

The matrix is then removed from the preconcentration<br />

column in a rinsing step and the clean and pH-neutral<br />

sample injected to the IC system.<br />

For liquid handling the 858 Professional Sample Processor<br />

– Pump – Injector is equipped with an additional<br />

valve. An additional peristaltic pump transfers the sample<br />

and rinsing solutions. The intelligent MagIC Net<br />

software controls and monitors the system.<br />

«ProfIC 10» is equipped with sequential suppression.<br />

Very high sensitivity is achieved by this unique combination<br />

of chemical and downstream CO 2<br />

suppression.<br />

The flexibility of the carbonate eluent is complemented<br />

by the low background conductivity of a hydroxide eluent.<br />

With the preconcentration technique, carbonate<br />

interference is practically eliminated.<br />

Ordering information<br />

ProfIC 10 - Anion<br />

«ProfIC 10 – Anion» – Professional IC<br />

system with inline sample preconcentration,<br />

matrix elimination and matrix<br />

neutralization<br />

Technical information<br />

Components<br />

1 x 2.850.2190 850 Professional IC Anion<br />

1 x 2.858.0030 858 Professional Sample Processor<br />

1 x 6.1602.150 Bottle neck attachment<br />

1 x 6.1608.070 Eluent bottle / 2 L / GL 45<br />

1 x 6.1825.230 PEEK sample loop 10 µL<br />

IC column, sample rack, sample vials as well as MagIC<br />

Net have to be ordered separately according to the<br />

particular application.<br />

The 858 Professional Sample Processor – Pump – Injector<br />

is responsible for sample delivery. Numerous sample<br />

racks for volumes 0.5...500 mL are available. Only<br />

small sample volumes of about 1 mL are normally<br />

required for matrix elimination and neutralization.<br />

«ProfIC 10» features intelligent system components<br />

such as the iPump and the iDetector and provides<br />

space for a total of three iColumns.<br />

34 — IC