Karl Fischer titration<br />

KF Coulometer<br />

756/831 KF Coulometer<br />

The Metrohm KF Coulometers are suitable for precise<br />

water determinations in the trace range (1ppm...10%).<br />

They are available with two different types of generator<br />

electrodes. The diaphragm-less generator electrode<br />

requires only one reagent and is practically maintenance-free.<br />

The use of the generator electrode with<br />

diaphragm is preferred for the following applications:<br />

very low water content (< 100 µg water absolute),<br />

when ketone reagents are used or with a high content<br />

of solubility promoter (> 10%).<br />

With or without printer – choose as you prefer! The<br />

756 KF Coulometer is equipped with a built-in thermal<br />

printer. However, just like the 831 KF Coulometer,<br />

you can also connect an external printer or connect<br />

the instrument to a PC, in which case you can choose<br />

between the Metrodata Vesuv and tiamo software.<br />

With our KF Coulometers you receive a complete titration<br />

cell and extensive accessories. KF Coulometers<br />

with the diaphragm generator electrode are delivered<br />

with the 728 Magnetic Stirrer as part of the accessories.<br />

Convincing arguments:<br />

• Live curve for early recognition of possible sidereactions<br />

• Simple operation due to dialog in German, English,<br />

French, Spanish, Italian, Portuguese and Swedish.<br />

• Expert or routine mode selectable<br />

• Internal memory for up to 100 methods<br />

Ordering information<br />

2.756.0010 756 KF Coulometer including generator<br />

electrode with diaphragm<br />

2.756.0110 756 KF Coulometer including diaphragmless<br />

generator electrode<br />

2.831.0010 831 KF Coulometer including generator<br />

electrode with diaphragm<br />

2.831.0110 831 KF Coulometer including<br />

diaphragmless generator electrode<br />

Options<br />

2.728.0010 728 Magnetic Swing-out Stirrer without<br />

stand<br />

2.703.0010 703 Titration Stand with Stirrer and<br />

Pump<br />

6.5617.000 Reagent changing equipment<br />

2.700.0020 700 Dosino<br />

2.140.0200 Impact printer CUSTOM DP40-S4N<br />

• With 2 x RS 232C (DB9) data interfaces for connection<br />

of balance, printer and PC<br />

• Possibility of connecting a PC keyboard and barcode<br />

reader<br />

• Optional: automatic reagent exchange using dosing<br />

unit and Dosino<br />

756 KF Coulometer with 728 Magnetic Stirrer and additional equipment<br />

for automatic reagent exchange<br />

— KF