UPP1-X In-Circuit Programmer with USB-2<br />

Project Download<br />

Projects can be downloaded to the UPP1’s SD card as described above in the AVRProg section above.<br />

Programming using the SD card<br />

PackProg is also able to program the AVR using one of the projects which are stored on the SD card<br />

of the UPP. This is described in detail in the AVRProg section above.<br />

Command line parameters<br />

In principle with all calls of PackProg switches can be appended. These are:<br />

-p Automatic programming start<br />

-v Verify target<br />

-f Verify flash only<br />

-u Check programmer<br />

-t Enable Telnet server<br />

-c Program exit<br />

-s No visual error messages are generated<br />

Instead the errors are written into the file ‘ISP_UPP.err’ in the program directory.<br />

‘Filename’ automatically opens and loads the PackFile defined with ‘Filename’.<br />

The order of the switches in the command line doesn’t matter. The switches must be separated by spaces. A<br />

switch must not contain spaces.<br />

Example: C:\pppp\PackProg.exe ‘abc.pac’ –d12345678 –p –c<br />

Return Codes<br />

These return codes can be used by a batch file to control its flow.<br />

0 dsOk Operation successful finished<br />

1 dsPwrDown No Target voltage<br />

2 dsPwrErr Target too high or too low<br />

3 dsFalseTyp Wrong CPU ID found<br />

4 dsProtect Target is protected by fuses<br />

5 dsNotEmpty Target is not empty after an erase<br />

6 dsVerifyErr Target or Programmer found a Verify error while programming<br />

7 dsFileError N.A.<br />

8 dsTimeOutErr USB driver returns a timeout<br />

9 dsCommError Communication problem with the Programmer<br />

10 dsNoProg Programmer not found<br />

11 dsNoProj Project not found<br />

12 dsFwLost Programmer returna an invalid firmware<br />

13 dsNotfound File, eg. Hexfile, was not found<br />