8<br />

Start-up procedure<br />

For first time start up it is necessary to set the DHW temperature<br />

knob and the space heating water temperature knob<br />

to the desired setting (see subsection 9.3.2 and 9.3.3).<br />

Factory setting is "0".<br />

100<br />

90<br />

110<br />

120<br />

130<br />

140<br />

90<br />

110<br />

130<br />

150<br />

170<br />

190<br />

WARNING<br />

There is a hot water scald potential if the BC10<br />

is set too high.<br />

8.3 Filling the condensate trap<br />

• Make sure that you fill the condensate trap with water.<br />

This is to prevent exhaust gases from entering the room.<br />

• Remove the condensate trap (see fig. 32) by disconnecting<br />

the connection to the heat exchanger and the<br />

connection to the condensate bypass pipe.<br />

• Fill with water and refit the condensate trap in reverse<br />

order.<br />

WARNING<br />

Danger of fatal accident due to poisoning. If the<br />

condensate trap is not filled with water, flue gas<br />

can escape and put people's lives at risk.<br />

Fig. 32<br />

Filling water into the condensate trap<br />

8.4 Bleeding the gas supply valve<br />

• Loosen the screw plug on the testing nipple for the gas<br />

connection and venting (fig. 33, pos. 1) by two turns and<br />

fit a hose.<br />

• Slowly open the gas shut-off valve.<br />

• Run the gas that is discharged through a water bath.<br />

• Close the gas shut-off valve when no more air is<br />

released.<br />

• Remove the hose and tighten the screw plug again.<br />

1<br />

8.5 Checking the combustion air/flue gas<br />

connection<br />

Check the following points:<br />

– Is the prescribed combustion air/flue system used?<br />

– Have the instructions for configuring the flue system as<br />

specified in the relevant Installation instruction for the flue<br />

gas system been observed?<br />

Fig. 33<br />

Bleeding the gas supply conduit<br />

32<br />

Logamax plus GB142-24/30/45/60 - We reserve the right to make any changes due to technical modifications!