1<br />
Safety and general instructions<br />
DANGER<br />
if flammable gas explodes.<br />
Beware if you smell gas: there may be an<br />
explosion hazard!<br />
Warning: If the information in these<br />
instructions is not followed exactly, a fire<br />
or explosion may result causing property<br />
damage, personal injury or death.<br />
• Do not store or use gasoline or other flammable<br />
vapors and liquids in the vicinity of<br />
this or any other boiler.<br />
What to do if you smell gas<br />
• Do not try to light any boiler.<br />
• Do not touch any electrical switch; do not<br />
use any phone in your building.<br />
• Immediately call your gas supplier from<br />
a neighbor’s phone. Follow the gas<br />
supplier’s instructions.<br />
• If you cannot reach your gas supplier, call<br />
the fire department.<br />
Installation and service must be performed by<br />
a qualified installer, service agency or the gas<br />
supplier.<br />
1.4 Observe these instructions for space<br />
heating water<br />
Unsuitable heating system water can promote the formation<br />
of scale or sludge, which affects system efficiency.<br />
It can also cause corrosion and reduce life of the heat<br />
exchanger.<br />
– You must follow <strong>Buderus</strong> guidelines for boiler water<br />
quality.<br />
– Thoroughly flush the system prior to filling.<br />
– Use of a <strong>Buderus</strong> approved boiler cleaner is<br />
recommended.<br />
– Never use salt bedding exchangers to soften the water.<br />
– Do not use inhibitors or other additives unless approved<br />
by <strong>Buderus</strong> for that purpose!<br />
– When frost protection of the heating system is desired,<br />
only use <strong>Buderus</strong>-approved Aluminum-safe antifreeze.<br />
– When using oxygen-permeable pipes, e. g. for floor<br />
heating systems, you must separate the system using<br />
heat exchangers.<br />
– The maximum permissible flow rate of the<br />
GB142-24/30 this is 11 GPM (gal./min.)(= 42 l/min.), for<br />
the GB142-45 is 15 GPM (= 57 l/min.) and for the<br />
GB142-60 is 20 GPM (= 76 l/min.).<br />
1.5 Tools, materials and additional<br />
equipment<br />
For the installation and maintenance of the boiler you will<br />
need the standard tools for space heating, gas and water<br />
fitting.<br />
In addition, a handtruck with a fastening belt is useful.<br />
1.6 Disposal<br />
– Dispose of the boiler packaging in an environmentally<br />
sound manner.<br />
– Dispose of components of the heating system (e. g.<br />
boiler or control device), that must be replaced in an<br />
environmentally responsible manner.<br />
6<br />