12<br />
Maintenance<br />
• Loosen both sets of retaining clips (fig. 44, pos. 4 and 5)<br />
of the burner cover and remove the burner cover with the<br />
fan unit and the gas burner fitting (fig. 45, pos. 1).<br />
• Remove the gas/air distributor plate (fig. 45, pos. 2), the<br />
orifice plate (GB142-24, GB142-30 and GB142-60 only,<br />
fig. 45, pos. 3) and the burner (fig. 45, pos. 4). Note that<br />
the orifice plate of the GB142-60 has a different shape.<br />
• Clean the gas/air distributor plate, the orifice plate<br />
(GB142-24, GB142-30 and GB142-60 only) and the<br />
burner using compressed air.<br />
1<br />
2<br />
3<br />
4<br />
• Remove the baffle plate and clean it using compressed<br />
air (fig. 46).<br />
Fig. 45<br />
Cleaning the burner cover, gas/air distributor plate,<br />
orifice plate and burner<br />
• Flush the heat exchanger with water.<br />
• Re-assemble all parts in reverse order of disassembly.<br />
NOTICE<br />
It is important to inspect and properly replace<br />
the rubber gaskets.<br />
Fig. 46<br />
Baffle plate<br />
• Switch on the heating system using the main switch.<br />
Fig. 47<br />
Cleaning the heat exchanger<br />
• Press the "Chimney Sweep" d button until the decimal<br />
point is displayed. Leave the boiler on for approx.<br />
10 minutes.<br />