15.04.2014 Views

Download - Buderus

Download - Buderus

Download - Buderus

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

10<br />

Shutting down the system<br />

10 Shutting down the system<br />

DANGER<br />

The heating system may freeze if it is not<br />

operational in times of frost.<br />

Protect the heating system against freezing if<br />

there is a danger of frost affecting the system.<br />

Drain the heating system water from the lowest<br />

point of the heating system.<br />

The vent screw at the highest point of the<br />

heating system must then be open.<br />

DANGER<br />

Should overheating occur or gas supply fail to<br />

shut off, turn off the manual gas control valve to<br />

the boiler.<br />

10.1 Shut down the heating system using the<br />

control unit<br />

Shut down your heating system using the BC10 basic<br />

controller. When the BC10 basic controller is shut down, the<br />

burner is also switched off automatically. Further information<br />

on how to operate the BC10 basic controller can be found in<br />

chapter 9 "BC10 basic controller", page 39.<br />

• Switch off the heating system using the main switch.<br />

• Close the main shut-off valve or the gas shut-off valve.<br />

10.2 Shutting down the heating system in the<br />

event of an emergency<br />

You must immediately close the main shut-off valve or gas<br />

shut-off valve and disconnect the power from the heating<br />

system.<br />

• Close the main shut-off valve.<br />

46<br />

Logamax plus GB142-24/30/45/60 - We reserve the right to make any changes due to technical modifications!

Hooray! Your file is uploaded and ready to be published.