9<br />

BC10 basic controller<br />

9.2 Carrying out additional tasks<br />

9.2.1 Carrying out a flue gas test<br />

The "Chimney Sweep" d button is used for the flue gas<br />

test.<br />

The heating control system works at the maximum flow<br />

temperature for 30 minutes. This is set on the BC10 basic<br />

controller using the "maximum heater temperature" knob.<br />

During flue gas testing the decimal point lights up in the<br />

display.<br />

• Press and hold the "Chimney Sweep" d button<br />

(< 5 seconds) until the decimal point is displayed.<br />

• Carry out the flue gas test.<br />

• Press the "Chimney Sweep" d button to interrupt the<br />

flue gas test.<br />

9.2.2 Selecting partial load operation (e. g. during flue<br />

gas testing)<br />

You can operate the boiler at a reduced boiler capacity<br />

during flue gas testing. This reduction is only effective for the<br />

duration of the flue gas test.<br />

• Press the "Chimney Sweep" d button (max. 2 seconds)<br />

until the decimal point shows in the status display. This<br />

will switch on the flue gas test.<br />

• Press and hold the "Chimney Sweep" d and "Service"<br />

e buttons (for approx. 5 seconds) to enter the partial<br />

load mode.<br />

• Press the "Reset" c button to reduce the boiler capacity<br />

percentage.<br />

+<br />

Example: boiler capacity reduced to 50 % of the rated boiler<br />

capacity.<br />

• Press the "Chimney Sweep" d button to increase the<br />

boiler capacity percentage.<br />

L50.<br />

• When test is completed, press the "Service" e button<br />

until the temperature indication is displayed.<br />

• Press the "Chimney Sweep" d button until the decimal<br />

point is cleared from the display.<br />

9.2.3 Switching the heating system to manual mode<br />

In manual mode the heating system can be operated independently<br />

of an external control unit. The boiler is operated<br />

with the heating system temperature set on the right knob<br />

serving as the target value.<br />

A blinking decimal point is displayed while manual mode is<br />

active.<br />

• Press the "Chimney Sweep" d button (for more than<br />

5 seconds) until the decimal point in the status display<br />

flashes.<br />

42<br />

Logamax plus GB142-24/30/45/60 - We reserve the right to make any changes due to technical modifications!