9<br />
BC10 basic controller<br />
Resetting the boiler or resetting faults<br />
If the boiler is down due to a fault, you can reset the boiler<br />
by pressing the "Reset" c button. This is only possible for<br />
so-called lock-out faults. There is another type of fault, socalled<br />
blocking faults, that reset themselves when the cause<br />
has been remedied.<br />
• Press the "Reset" c button to reset the boiler.<br />
The display shows "rE" while resetting.<br />
It is only possible to reset the boiler when a lock-out code<br />
(blinking fault code) is visible in the display.<br />
rE<br />
NOTICE<br />
If the burner returns to fault mode after resetting<br />
the boiler, you must resolve the fault using the<br />
servicing section in this document.<br />
Contact your supplier if necessary.<br />
9.1.3 Displaying the heating system status and/or<br />
faults<br />
The display of the BC10 basic controller shows the status of<br />
the heating system.<br />
In the event of a fault the display immediately shows the fault<br />
or the warning in the form of an error code (see<br />
subsection 13.2). The status display will flash if the fault is a<br />
lock-out fault.<br />
• Press the "Service" e button to switch between status<br />
displays or to read out the service and error codes.<br />
• Resolve the fault see subsection 13.3.<br />
The following status displays can be seen depending on the<br />
operating conditions:<br />
Displays<br />
(examples)<br />
Values Meaning Operating condition/Remedy<br />
140<br />
P12<br />
H 7<br />
1)<br />
P21<br />
-H<br />
1)<br />
(changing)<br />
-H<br />
140<br />
P12<br />
number 0 ... 199 2)<br />
Current boiler water temperature (in °F)<br />
> P15 Current system pressure (in psi) Normal operating conditions<br />
P3 ... P12<br />
number 0 ... 199 2)<br />
P3 ... P12<br />
Warning:<br />
System pressure is too low (between 3 and 12 psi<br />
= 0.2 and 0.8 bar)<br />
Current boiler water temperature (in °F)<br />
Current system pressure (in psi)<br />
Warning<br />
Heating system remains operational<br />
between 12 psi and 3 psi (0.8 and 0.2 bar).<br />
Fill the heating system and restore the<br />
minimum filling pressure ( 14.5 psi =<br />
1.0 bar).<br />
The system pressure is shown for<br />
10 minutes after which the standard<br />
display returns.<br />
Table 8<br />
Possible status displays<br />
1) Standard display for this operating condition. This display appears after 5 minutes if no button is pressed.<br />
2)<br />
The temperature is higher as 199° when 199 is blinking in the display.<br />
40<br />
Logamax plus GB142-24/30/45/60 - We reserve the right to make any changes due to technical modifications!