Indeed, there will be cases where a user job will die prior to the HA software<br />

triggering a failover. You can certainly shorten timeouts, add monitoring, and take<br />

other steps to decrease this probability. But there is a serious trade-off – shortening<br />

timeouts increases the probability of false-triggering a busy system. Increasing<br />

monitoring takes the system resources, and can likewise cause a false trigger.<br />

Unfortunately, hard failover solutions capable of catching failures in the sub-second<br />

range generally require special hardware. As a result, they are quite expensive.<br />

Tip – Failover of the <strong>Lustre</strong> client is dependent on the obd_timeout parameter. The<br />

<strong>Lustre</strong> client does not attempt failover until the request times out. Then, the client<br />

tries resending the request to the original server (if again, an obd_timeout occurs).<br />

After that, the <strong>Lustre</strong> client refers to the import list for that target and tries to<br />

connect (in a round-robin manner) until one of the nodes replies. The timeouts for<br />

the connection are much lower (obd_timeout / 20, 5).<br />

8-22 <strong>Lustre</strong> <strong>1.6</strong> <strong>Operations</strong> <strong>Manual</strong> • September 2008