(l) Remove test button (11) from staple (12).<br />
(m) Remove facepiece assembly.<br />
NOTE<br />
A retaining ring (part of staple kit) maybe used if a retainer clip is lost or<br />
damaged, or if facial features of soldier cause distortion in facepiece that would<br />
prevent locking of retainer clip on IPD staple post.<br />
(n) Install one retainer clip (15) on IPD staple post (13) as follows:<br />
(1)<br />
(2)<br />
(3)<br />
Position slotted hole of retainer clip (15) on top of IPD staple post (13) with vertical piece of clip<br />
pointing upward and away from lens.<br />
Grasp vertical piece of retainer clip (15) and pull away from facepiece assembly (14), approximately<br />
1/16-inch, until groove in IPD staple post (13) is seated in slot of retainer clip.<br />
Rotate retainer clip (15) towards bridge of nose until hole in clip snaps over button on<br />
staple (12).<br />
(o) Repeat step (n) to install other retainer clip (15).<br />
(p) Obtain filler button (16) from plastic bag.<br />
(q) Position filler button (16) over top of keyway in staple (12) and press button into keyway.<br />
13. Repeat steps 1 thru 7.<br />