<strong>TM</strong> 3-<strong>4240</strong>-<strong>334</strong>-20&P<br />

Item<br />

No.<br />

lnterval<br />

Item to<br />

Check/Service<br />

Procedure<br />

Not Fully Mission<br />

Capable If:<br />

11<br />

Semi-<br />

Annual<br />

BLOWER<br />

ASSEMBLY<br />

a.<br />

Check air distribution tubes (1)<br />

for cracks, breaks, and<br />

alinement.<br />

Air distribution tubes are cracked<br />

broken, or bent.<br />

b.<br />

Check that wiper seals (2) are<br />

not cut, torn, or missing.<br />

Either wiper seal is cut, torn, or<br />

missing.<br />

c.<br />

Ensure that both snap hooks<br />

(3) are present.<br />

Snap hooks are missing.<br />

d.<br />

Check that blower assembly<br />

release D-ring (4) and latch pin<br />

(5) work properly.<br />

Blower release latch pin does<br />

not retract.<br />

e.<br />

Check that knob (6), pushbutton<br />

(7), and LED (8) are<br />

present and not broken.<br />

Knob, pushbutton, or LED is<br />

missing or broken.<br />

CAUTION<br />

Do not attempt to tighten or<br />

adjust screw; damage to<br />

blower assembly may<br />

result.<br />

f.<br />

Check screw (9) for red antitamper<br />

seal.<br />

Red anti-tamper seal is cracked,<br />

chipped or broken, indicating<br />

possible screw rotation.<br />

2-27