3 U238 The position of the second nuclide in the same material. Count the position in the<br />

order of material specification.<br />

4 IX Mesh number of X-direction where the neutron spectrum is obtained. Enter<br />

R-Region number <strong>for</strong> the collision probability calculation as it can be assumed as<br />

one-dimensional calculation.<br />

5 IY Mesh number of Y-direction where the neutron spectrum is obtained.<br />

Enter IY=0 <strong>for</strong> one-dimensional calculation.<br />

6 IZ Mesh number of Z-direction where the neutron spectrum is obtained. Enter IZ=0<br />

<strong>for</strong> one- and two-dimensional calculations.<br />

(FGS (g),g=1,IGMAX)<br />

Filter transmission by energy group(g), where 0 ≤ f g ≤ 1. They are applied in<br />

Eqs.(2.10-9) and (2.10-10). IGMAX is number of energy groups (IGMAX=NEF+<br />

NET <strong>for</strong> fine group calculation and IGMAX=NERF+NERT <strong>for</strong> few group one, cf.<br />

Sect.2.2)<br />

Repeat Block-4-1 IOPT(3) times.<br />

--------------------------------------------------------------------------------------------------------------------------<br />

Block-5-1 Required if IOPT(4)>0 and after CITATION calculation /1/<br />

NZONE Number of zones used in CITATION calculation (=NM of Block-1 in Sect.2.8)<br />

Block-5-2 Required if IOPT(4)>0 and after CITATION calculation /A8/<br />

MTNAME(i) Material name of the detec<strong>to</strong>r assigned <strong>to</strong> zone i.<br />

The member of this name must be prepared on MACRO or MACROWRK file.<br />

The fifth character (e-tag) and the eighth one (p-tag) may be arbitrary as they are<br />

specified by the code (cf. Sect.2.9).<br />

If a blank material name is entered, the corresponding zone is excluded from the<br />

integration.<br />

Repeat Block-5-2 NZONE times.<br />

Block-5-3 Required if IOPT(4)>0 and after CITATION calculation /2/<br />

133