VIKING PIPE STAND Part No. VA-F1PS<br />

For <strong>Viking</strong> F-1 & R-6 Vehicular Gate Operator<br />

Standard Features<br />

• Main pieces made of 1/4” thick material<br />

• All hardware included<br />

<strong>Installation</strong><br />

1. Remove Chassis Reinforcement Brackets and Bolts<br />

2. Place Operator on Pipe Stand<br />

3. Replace Chassis Reinforcement Brackets<br />

4. Attach the Operator and Brackets to the Pipe Stand<br />

using the Mounting Bolts, Nuts and Washers<br />

supplied with the Pipe Stand<br />

5. Tighten Bolts securely<br />

6. Refer to F-1 or R-6 <strong>Manual</strong> for Plan of <strong>Installation</strong><br />

3.05" I.D.<br />

F-1 Gate Operator<br />

(sold separately)<br />

3.10"<br />

10.85"<br />

2.15"<br />

Mounting Bolt<br />

Washer<br />

Reinforcement<br />

Bracket<br />

F-1 or R-6<br />

Gate Operator<br />

13.49"<br />

8.05" 2.79"<br />

3.00"O.D. Pipe<br />

(Maximum)<br />

Pipe Stand<br />

Washer<br />

Mounting Nut<br />

Secure Stand to Pipes<br />

Using (6) Supplied Bolts<br />

Note:<br />

All Mounting Hardware<br />

Supplied with Pipe Stand<br />

Grade Level<br />

Consult Local Codes<br />

for Depth and Concrete<br />

Requirements<br />

34<br />