ARTICLE 310 -<br />

CONDUCTORS FOR GENERAL WIRING<br />

310.60<br />

n\ .5<br />

. \tJ.,.,<br />

" .<br />

.' ,<br />

.....<br />

~<br />

E<br />

- E<br />

'I . ,u 0<br />

~<br />

Detail 1<br />

0><br />

290 mm x 290 mm ~<br />

(11.5 in. x 11.5 in.) 190 mm (7.5 in.)<br />

Electrical duct bank<br />

Detail 2<br />

One electrical duct<br />

475 mm x 475 mm<br />

(19 in. x 19 in.)<br />

190 mm (7.5 in.)<br />

Electrical duct bank<br />

Three electrical ducts Detail 3<br />

or<br />

475 mm x 675 mm<br />

(19 in. x 27 in.)<br />

, ,<br />

'<br />

Electrical duct bank<br />

. v • 'I Six electrical ducts<br />

~ or<br />

190 mm 190 mm<br />

(7.5 in.) (7.5 in.) .5<br />

It)<br />

675 mm x 290 mm<br />

(27 in. x 11.5 in.)<br />

Electrical duct bank<br />

Three electrical ducts<br />

t:::.<br />

E<br />

E<br />

o<br />

0><br />

~<br />

190 mm 190 mm<br />

(7.5 in.) (7.5 in.)<br />

675 mm x 475 mm<br />

(27 in. x 19 in.)<br />

Electrical duct bank<br />

Six electrical ducts<br />

r<br />

600mm<br />

600mm<br />

(24 in.) (24 in.) ~<br />

.­<br />

• 1 I. •• .'.<br />

DetailS Detail 6 Detail7 Detail 8<br />

Buried 3 Buried 3 Buried triplexed Buried triplexed<br />

conductor conductor cables (1 circuit) cables (2 circuits)<br />

cable<br />

cables<br />

190<br />

rn<br />

mm 190 mm 190 mm 190 mm 190 mm<br />

(7.5 in.) (7.5 in.) (7.5 in.) (7.5 in.) 600mm<br />

(7.5 in.)<br />

(24 in.)<br />

Detail 9<br />

Detail 10<br />

Buried single-conductor<br />

Buried single-conductor<br />

cables (1 circuit)<br />

cables (2 circuits)<br />

Legend<br />

Note: Minimum burial depths to top electrical ducts or cables shall be<br />

in accordance with 300.50. Maximum depth to the top of electrical<br />

duct banks shall be 750 mm (30 in.) <strong>and</strong> maximum depth to the top<br />

of direct buried cables shall be 900 mm (36 in,).<br />

G:] Backfill (earth or concrete)<br />

o Electrical duct<br />

• Cable or cables<br />

Figure 310.60 Cable Installation Dimensions for Use with Table 310.77 Through Table 310.86.<br />

2008 Edition NATIONAL ELECTRICAL CODE 70-155