<strong>Vigilohm</strong>: installation and connection<br />

connection (cont.)<br />

When coupling two installations, one of the<br />

two <strong>Vigilohm</strong> insulation monitors must be<br />

disconnected momentarily.<br />

E12008<br />

IMD<br />

MV<br />

LV<br />

IMD<br />

MV<br />

LV<br />

E27111<br />

E24322<br />

TR22A/TR22AH<br />

MERLIN GERIN<br />

vigilohm<br />

TR 22AH<br />

test<br />

K Ω<br />

E18471<br />

aa<br />

1 2 3<br />

TR22A<br />

TR22AH<br />

4 8 9<br />

U < 760 V U < 440 V U < 760 V U < 440 V<br />

MV/LV<br />

cardew C<br />

L3<br />

L2<br />

L1<br />

N<br />

5<br />

TR<br />

22A<br />

4<br />

E24323<br />

MV/LV<br />

cardew C<br />

L3<br />

L2<br />

L1<br />

5<br />

TR<br />

22A<br />

4<br />

E24324<br />

LV/LV<br />

5<br />

TR<br />

22A<br />

4<br />

L3<br />

L2<br />

L1<br />

N<br />

E24325<br />

LV/LV<br />

ut<br />

7<br />

5<br />

TR<br />

22A<br />

4<br />

L3<br />

L2<br />

L1<br />

rS3P1<br />

5 6 10<br />

E26347<br />

U < 1700 V<br />

1<br />

P1<br />

5<br />

6<br />

10<br />

TR<br />

22A<br />

4<br />

L1<br />

L2<br />

L3<br />

N<br />

E26346<br />

2.5 mm 2 wiring<br />

Legend:<br />

aa: AC auxiliary supply, 50-60 Hz<br />

-15 %, +10 %<br />

12 1 3<br />

110-127 V a 110-127 V<br />

220/415 V a 220-240 V 380-415 V<br />

440/525 V a 440-480 V 500-525 V<br />

r: installation<br />

S3: S3 subassembly (optional)<br />

ut: application<br />

P1: P1 subassembly (optional)<br />

Use with failsafe feature: the normally<br />

excited output relay is de-energised in the<br />

event of an auxiliary voltage failure (of<br />

internal or external origin) or an insulation<br />

fault.<br />

auxiliary: S3 inductive<br />

U < 1000 V neutral point subassembly<br />

1<br />

6<br />

P1<br />

5<br />

10<br />

TR<br />

22A<br />

4<br />

L1<br />

L2<br />

L3<br />

E24326<br />

1 2 3<br />

4<br />

S3<br />

L3<br />

L2<br />

L1<br />

N<br />

6<br />

TR<br />

22A<br />

4<br />

E27134<br />

TR5A<br />

E26417<br />

1<br />

r<br />

2<br />

+<br />

TR5A<br />

2.5 mm 2 wiring<br />

6.35 mm tab connector<br />

Legend:<br />

r: installation DC power supply, - 20 %, + 20 %<br />

ut: application<br />

r > 220 V<br />

MERLIN GERIN<br />

TR5A<br />

3<br />

6 7 8<br />

E18566<br />

1 2<br />

3<br />

TR5A<br />

9<br />

r<br />

– +<br />

1 2 3 4<br />

auxiliary<br />

5 plate TR5A<br />

u. t.<br />

Note: for a TR5A with failsafe feature, use terminals<br />

6 and 7.<br />

E26418<br />

2<br />

TR<br />

5A<br />

1<br />

3<br />

+<br />

E27112<br />

SM21<br />

MERLIN GERIN<br />

vigilhom<br />

SM21<br />

1 2 3 4 5 6 7<br />

0,75<br />

0,5<br />

1,0 1,25<br />

1,5<br />

1,75 1,0<br />

1,5<br />

2,0 3,0<br />

AL. REL.<br />

OK<br />

5,0<br />

7,5<br />

test<br />

o f on<br />

E26348<br />

alarm<br />

1 2 3<br />

8 9<br />

SM21<br />

11 13<br />

pre-alarm<br />

5 6 7<br />

E26349<br />

2.5 mm 2 wiring<br />

Legend:<br />

aa: supply<br />

L1<br />

L2<br />

L3<br />

N<br />

13<br />

SM<br />

21<br />

11<br />

M<br />

50761<br />

0,25<br />

Sa<br />

2,0<br />

MΩ<br />

0,5 10<br />

Sp<br />

AL. REL.<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

a. a.<br />

c. a.<br />

Note: make sure that the auxiliary contact of the motor<br />

control system can withstand the rated voltage when the<br />

contact is open.<br />

52