21.11.2014 Views

Vigilohm System - engineering site - Schneider Electric

Vigilohm System - engineering site - Schneider Electric

Vigilohm System - engineering site - Schneider Electric

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MERLIN GERIN<br />

vigilohm system<br />

XML31 6<br />

1<br />

9<br />

2 3 4 5 6 7 8<br />

10 11 12 13 14 15 16<br />

MERLIN GERIN<br />

vigilohm system<br />

XD308c<br />

MERLIN GERIN<br />

vigilohm system<br />

XM300c<br />

040 K<br />

MERLIN GERIN<br />

vigilohm system<br />

XM200<br />

R C Sp Sa<br />

vigilohm system<br />

XL316<br />

1 2 3 4 5 6 7 8<br />

test<br />

vigilohm system<br />

XD301<br />

50507<br />

1 2 3<br />

4 5 6<br />

7 8 9<br />

10 11 12<br />

MERLIN GERIN<br />

reset<br />

test<br />

on<br />

M<br />

M<br />

S<br />

test<br />

menu ok test<br />

valeur d'isolement<br />

040 K<br />

TEST MENU<br />

test<br />

reset<br />

vigilohm system<br />

XD312<br />

50536<br />

1<br />

9<br />

2<br />

10<br />

3<br />

11<br />

4<br />

12<br />

5<br />

13<br />

6<br />

14<br />

M<br />

M<br />

test<br />

7<br />

15<br />

8<br />

16<br />

test<br />

test/reset<br />

test<br />

reset<br />

test<br />

Catalogue numbers<br />

<strong>Vigilohm</strong> <strong>System</strong><br />

Monitors<br />

E27115<br />

E27126<br />

Monitors-locators<br />

E32439<br />

Locators<br />

E32441<br />

Detectors<br />

E27126<br />

E27125<br />

E32443<br />

MERLIN GERIN<br />

valeur d'isolement<br />

TEST MENU<br />

MERLIN GERIN<br />

Type of installation to be<br />

monitored:<br />

XM300C<br />

Single phase auxiliary power<br />

supply (V)<br />

XM200<br />

Single phase auxiliary power<br />

supply (V)<br />

Type of installation to be monitored: see XM300C IMD<br />

XML308<br />

Single phase auxiliary power<br />

supply (V)<br />

XML316<br />

Single phase auxiliary power<br />

supply (V)<br />

Type of installation to be monitored: see XM300C IMD<br />

XL308<br />

Single phase auxiliary power<br />

supply (V)<br />

XL316<br />

Single phase auxiliary power<br />

supply (V)<br />

Type of installation to be monitored: see XM300C IMD<br />

XD308C<br />

Single phase auxiliary power<br />

supply (V)<br />

Type of installation to be monitored: see XM200 IMD<br />

XD301<br />

Single phase auxiliary power<br />

supply (V)<br />

XD312<br />

Single phase auxiliary power<br />

supply (V)<br />

AC or mixed IT Neutral distributed Voltage < 760 V AC (45/400 Hz)<br />

Neutral not distributed Voltage < 440 V AC (45/400 Hz)<br />

DC or rectified Line voltage < 500 V DC<br />

115/127 V AC 50/60 Hz 50540<br />

220/240 V AC 50/60 Hz 50541<br />

380/415 V AC 50/60 Hz 50542<br />

500/525 V AC 50/60 Hz 50543<br />

115/127 V AC 50/60 Hz 50727<br />

220/240 V AC 50/60 Hz 50728<br />

380/415 V AC 50/60 Hz 50729<br />

500/525 V AC 50/60 Hz 50730<br />

115/127 V AC 50/60 Hz 50490<br />

220/240 V AC 50/60 Hz 50491<br />

380/415 V AC 50/60 Hz 50492<br />

500/525 V AC 50/60 Hz 50493<br />

115/127 V AC 50/60 Hz 50322<br />

220/240 V AC 50/60 Hz 50323<br />

380/415 V AC 50/60 Hz 50324<br />

500/525 V AC 50/60 Hz 50325<br />

115/127 V AC 50/60 Hz 50606<br />

220/240 V AC 50/60 Hz 50607<br />

380/415 V AC 50/60 Hz 50608<br />

500/525 V AC 50/60 Hz 50609<br />

115/127 V AC 50/60 Hz 50615<br />

220/240 V AC 50/60 Hz 50616<br />

380/415 V AC 50/60 Hz 50617<br />

500/525 V AC 50/60 Hz 50618<br />

115/127 V AC 50/60 Hz 50723<br />

220/240 V AC 50/60 Hz 50724<br />

380/415 V AC 50/60 Hz 50725<br />

500/525 V AC 50/60 Hz 50726<br />

115/127 V AC 50/60 Hz 50506<br />

220/240 V AC 50/60 Hz 50507<br />

380/415 V AC 50/60 Hz 50508<br />

500/525 V AC 50/60 Hz 50509<br />

115/127 V AC 50/60 Hz 50535<br />

220/240 V AC 50/60 Hz 50536<br />

380/415 V AC 50/60 Hz 50537<br />

500/525 V AC 50/60 Hz 50538<br />

58

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!