Vigilohm System - engineering site - Schneider Electric
Vigilohm System - engineering site - Schneider Electric
Vigilohm System - engineering site - Schneider Electric
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
on P12<br />
MERLIN GERIN<br />
vigidix<br />
RM 10N<br />
vigilhom<br />
50761<br />
P50<br />
P1 0<br />
vigilohm<br />
TR5A<br />
120V<br />
1 2 3 4 5<br />
6 7 8 9 10<br />
50381<br />
0,75<br />
0,5<br />
1,0 1,25<br />
0,25<br />
Sa<br />
2,0<br />
1,5<br />
1,75<br />
1,5<br />
1,0<br />
2,0 3,0<br />
0,5<br />
Sp<br />
10<br />
5,0<br />
7,5<br />
o f on<br />
test<br />
20 35<br />
10<br />
50<br />
Catalogue numbers<br />
<strong>Vigilohm</strong> insulation<br />
monitoring (cont.)<br />
<strong>Vigilohm</strong> TR5A<br />
E32741<br />
1 2 3 4 5<br />
MERLIN GERIN<br />
6 7 8 9 1<br />
0<br />
1<br />
0<br />
kΩ<br />
Installation voltage (neutral not distributed): < 420 V DC<br />
(adjustable threshold 5-150 kΩ)<br />
TR5A<br />
Standard model<br />
Fail safe model<br />
Power supplied by monitored 24 V DC 50340 50344<br />
installation (V)<br />
42/48 V DC 50341 50345<br />
120 V DC 50342 50346<br />
220 V DC 50343 50347<br />
260 V DC<br />
(1)<br />
50350<br />
420 V DC<br />
(1)<br />
50351<br />
(1) with supplied external subassembly.<br />
<strong>Vigilohm</strong> SM21<br />
E58548<br />
Installation voltage: < 690 V (1)<br />
SM21<br />
Single phase auxiliary power<br />
supply (V)<br />
115/127 V AC 50/60 Hz 50760<br />
220/240 V AC 50/60 Hz 50761<br />
380/415 V AC 50/60 Hz 50762<br />
440/480 V AC 50/60 Hz 50763<br />
500/525 V AC 50/60 Hz 50764<br />
(1) this voltage is depends on the rated voltage withstand performance of the open auxiliary contact used to isolate the SM21 from<br />
the installation.<br />
Mobile 2.5 Hz fault locating<br />
Kit case<br />
Mobile fault locating kit case containing:<br />
XGR (220/240 V) + XRM + XP15 + XP50 + XP100 probes<br />
Mobile XGR generator<br />
E32436<br />
Mobile detector and probes<br />
E27131 / 27129<br />
MERLIN GERIN<br />
SM21<br />
1 2 3 4 5 6 7<br />
8<br />
9<br />
1<br />
1<br />
MΩ<br />
MERLIN GERIN<br />
1<br />
AL. REL.<br />
OK<br />
1<br />
1<br />
test<br />
AL. REL.<br />
Single phase auxiliary power<br />
supply (V)<br />
50310<br />
115/127 V AC 50/60 Hz 50281<br />
220/240 V AC 50/60 Hz 50282<br />
380/415 V AC 50/60 Hz 50283<br />
500/525 V AC 50/60 Hz 50284<br />
XRM and XP15 probe 50277<br />
XRM and XP50 probe 50287<br />
XRM and XP100 probe 50288<br />
XRM and XP50 + XP100 probes 50289<br />
XP15 probe<br />
Empty case for mobile fault locating kit<br />
Auxiliaries<br />
<strong>Vigilohm</strong><br />
TR22A<br />
TR22AH<br />
EM9<br />
EM9B<br />
EM9BV<br />
EM9T<br />
TR5A<br />
SM21<br />
50494<br />
50285<br />
"250 V" Cardew C or b b (1) 50170<br />
"440 V" Cardew C or b b (1) 50171<br />
"660 V" Cardew C or b b (1) 50172<br />
"1 000 V" Cardew C b b (1) 50183<br />
Cardew C base v v 50169<br />
P1 subassembly b 50211<br />
ZX limiting impedance v v 50159<br />
S3 inductive neutral point v v 50113<br />
b compulsory auxiliary<br />
v optional auxiliary<br />
(1) Use of the Cardew C is not compulsory with the EM9T.<br />