09.11.2012 Views

Totally Integrated Automation - Automation Technology - Siemens

Totally Integrated Automation - Automation Technology - Siemens

Totally Integrated Automation - Automation Technology - Siemens

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

Industrial communication<br />

AS-Interface<br />

AS-Interface is the simple, low-cost, effective<br />

networking system for the field level.<br />

Data and energy are transferred over a single<br />

cable. As an open manufacturer-independent<br />

bus system, it transfers digital and<br />

analog signals that are closely related to the<br />

process and machine. On the other hand it<br />

also functions as a universal interface<br />

between simple binary actuators and sensors as well as to the higher<br />

control levels – for standard and safety engineering. (for ASIsafe, also<br />

refer to the Safety <strong>Integrated</strong> section)<br />

Thanks to the AS-i master for interfacing to SIMATIC or the routers to<br />

PROFIBUS or PROFINET, AS-Interface can be completely integrated in<br />

TIA. All the diagnostic information of the AS-Interface network is then<br />

available in the controller plant wide and can be read out, for example,<br />

using Operator Panels or in the control room.<br />

Fail-safe communication –<br />

ASIsafe<br />

For further information about ASIsafe, refer to the chapter<br />

Safety <strong>Integrated</strong> on page 97.<br />

Connecting AS-Interface to the controller -<br />

CPs for SIMATIC<br />

Make your controller fit and ready for connection to AS-Interface<br />

• Plug-in modules to AS-i Spec. 3.0 for<br />

connection to the backplane bus of the<br />

controller<br />

• The controller becomes an AS-Interface<br />

master and offers support for as many as<br />

62 AS-Interface slaves (A/B system)<br />

• Fast display of the slave states by means of<br />

LEDs on the front panel<br />

• <strong>Integrated</strong> analog value transmission<br />

• No configuration necessary; optional for<br />

S7-300: Upload the AS-i configuration into<br />

STEP 7<br />

Routers –<br />

ASIsafe<br />

Further information about routers for AS-Interface can be found in this<br />

chapter on page 132 et seq.<br />

126 <strong>Siemens</strong> TIA Product Guide 2011<br />

© <strong>Siemens</strong> AG 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!