Industrial communication<br />
AS-Interface<br />
AS-Interface is the simple, low-cost, effective<br />
networking system for the field level.<br />
Data and energy are transferred over a single<br />
cable. As an open manufacturer-independent<br />
bus system, it transfers digital and<br />
analog signals that are closely related to the<br />
process and machine. On the other hand it<br />
also functions as a universal interface<br />
between simple binary actuators and sensors as well as to the higher<br />
control levels – for standard and safety engineering. (for ASIsafe, also<br />
refer to the Safety <strong>Integrated</strong> section)<br />
Thanks to the AS-i master for interfacing to SIMATIC or the routers to<br />
PROFIBUS or PROFINET, AS-Interface can be completely integrated in<br />
TIA. All the diagnostic information of the AS-Interface network is then<br />
available in the controller plant wide and can be read out, for example,<br />
using Operator Panels or in the control room.<br />
Fail-safe communication –<br />
ASIsafe<br />
For further information about ASIsafe, refer to the chapter<br />
Safety <strong>Integrated</strong> on page 97.<br />
Connecting AS-Interface to the controller -<br />
CPs for SIMATIC<br />
Make your controller fit and ready for connection to AS-Interface<br />
• Plug-in modules to AS-i Spec. 3.0 for<br />
connection to the backplane bus of the<br />
controller<br />
• The controller becomes an AS-Interface<br />
master and offers support for as many as<br />
62 AS-Interface slaves (A/B system)<br />
• Fast display of the slave states by means of<br />
LEDs on the front panel<br />
• <strong>Integrated</strong> analog value transmission<br />
• No configuration necessary; optional for<br />
S7-300: Upload the AS-i configuration into<br />
STEP 7<br />
Routers –<br />
ASIsafe<br />
Further information about routers for AS-Interface can be found in this<br />
chapter on page 132 et seq.<br />
126 <strong>Siemens</strong> TIA Product Guide 2011<br />
© <strong>Siemens</strong> AG 2011