<strong>Automation</strong> software<br />

Energy management with SIMATIC WinCC<br />

Powerrate<br />

© <strong>Siemens</strong> AG 2011<br />

Energy management –<br />

SIMATIC powerrate, B.Data system and SENTRON PAC3200 for WinCC<br />

• Identification of energy-intensive loads and<br />

processes for the purpose of deriving measures<br />

for improving power efficiency<br />

• Comparison of consumption profiles for<br />

more efficient processes<br />

• Optimizing the company according to energy<br />

parameters based on an assessment of<br />

consumption and costs<br />

• Reducing the energy costs by complying with agreed power limits<br />

• Production data and energy data can be correlated thanks to the integration<br />

of EM functionality based on the PCS 7 and WinCC standard systems<br />

B.Data<br />

• Combining the technical and commercial<br />

data processing systems creates companywide<br />

transparency, thanks to continuous<br />

energy and materials balancing for the<br />

power generation systems and loads.<br />

• Generation of characteristic values for well-informed statements on<br />

increasing the efficiency of power generation and distribution systems<br />

and loads supports costs-by-cause energy cost accounting and transfer<br />

to the billing system (e.g. SAP R/3)<br />

• Planning certainty through production-related load and demand forecasts<br />

supports energy purchasing decisions<br />

• Fulfilment of the legal obligations for monitoring and reporting on<br />

greenhouse gas emissions (CO2 emissions)<br />

PAC3200<br />

• For seamless integration of the PAC3200<br />

Power Monitoring Device into SIMATIC<br />

WinCC<br />

• Total integration of SENTRON PAC3200 in<br />

SIMATIC WinCC over PROFIBUS<br />

• DPV1 by means of certified WinCC add-on<br />

module<br />

• Read-out and display of measured values<br />

and device data<br />

• Input of limit values for monitoring by the driver module<br />

• Resetting of values on the device (min./max. values)<br />

• Product components: Driver block, diagnostic data block, faceplates<br />

<strong>Siemens</strong> TIA Product Guide 2011<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

75

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!