Fail-safe communication –<br />

ASIsafe<br />

Connecting sensors easily and reliably<br />

Safety <strong>Integrated</strong><br />

• Safety technology with AS-Interface:<br />

ASIsafe with standard and safety data on a<br />

single bus<br />

• Certified to PL e acc. to ISO 13849-1,<br />

Cat. 4 acc. to EN 954-1 or up to SIL 3 acc.<br />

to IEC 61508<br />

• All ASIsafe components are fully compatible<br />

with all standard components of<br />

AS-Interface in accordance with<br />

AS-Interface standard EN 50295<br />

• Up to 31 safe slaves in one AS-i network<br />

• Stand-alone solution using safety monitor (ASIsafe Solution local)<br />

• Connection of ASIsafe to PROFIsafe thanks to DP/AS-i F-Link (ASIsafe<br />

Solution PROFIsafe) with programming via SIMATIC STEP 7 Distributed<br />

Safety<br />

Fail-safe communication –<br />

ASIMON V3<br />

© <strong>Siemens</strong> AG 2011<br />

ASIsafe Solution local with AS-i safety monitor<br />

• The ASIMON PC software is used for<br />

configuring the AS-Interface safety monitor.<br />

• Using the online function of the software,<br />

the current status of the configured logic<br />

blocks can be read on site and monitored in<br />

the pixel-graphics diagnostic view.<br />

• The desired status information is provided in intuitive color changes<br />

of the blocks and connecting lines (green/yellow/red). This function<br />

is especially valuable during commissioning and troubleshooting.<br />

Fail-safe communication –<br />

ASIsafe module S45F with fail-safe AS-i output<br />

Greater flexibility - Safe switch-off with ASIsafe<br />

• The fail-safe SlimLine module S45F allows<br />

fail-safe connection of actuators via<br />

AS-Interface in a distributed configuration.<br />

• The fail-safe output can be installed anywhere<br />

on the AS-Interface and is activated<br />

via the safety monitor.<br />

• The module is suitable for safety applications<br />

up to SIL 3 or PL e.<br />

• The S45F is also equipped with standard<br />

inputs and outputs, for functional switching<br />

of an actuator, for example.<br />

<strong>Siemens</strong> TIA Product Guide 2011<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

97

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!