Fail-safe communication –<br />
ASIsafe<br />
Connecting sensors easily and reliably<br />
Safety <strong>Integrated</strong><br />
• Safety technology with AS-Interface:<br />
ASIsafe with standard and safety data on a<br />
single bus<br />
• Certified to PL e acc. to ISO 13849-1,<br />
Cat. 4 acc. to EN 954-1 or up to SIL 3 acc.<br />
to IEC 61508<br />
• All ASIsafe components are fully compatible<br />
with all standard components of<br />
AS-Interface in accordance with<br />
AS-Interface standard EN 50295<br />
• Up to 31 safe slaves in one AS-i network<br />
• Stand-alone solution using safety monitor (ASIsafe Solution local)<br />
• Connection of ASIsafe to PROFIsafe thanks to DP/AS-i F-Link (ASIsafe<br />
Solution PROFIsafe) with programming via SIMATIC STEP 7 Distributed<br />
Safety<br />
Fail-safe communication –<br />
ASIMON V3<br />
© <strong>Siemens</strong> AG 2011<br />
ASIsafe Solution local with AS-i safety monitor<br />
• The ASIMON PC software is used for<br />
configuring the AS-Interface safety monitor.<br />
• Using the online function of the software,<br />
the current status of the configured logic<br />
blocks can be read on site and monitored in<br />
the pixel-graphics diagnostic view.<br />
• The desired status information is provided in intuitive color changes<br />
of the blocks and connecting lines (green/yellow/red). This function<br />
is especially valuable during commissioning and troubleshooting.<br />
Fail-safe communication –<br />
ASIsafe module S45F with fail-safe AS-i output<br />
Greater flexibility - Safe switch-off with ASIsafe<br />
• The fail-safe SlimLine module S45F allows<br />
fail-safe connection of actuators via<br />
AS-Interface in a distributed configuration.<br />
• The fail-safe output can be installed anywhere<br />
on the AS-Interface and is activated<br />
via the safety monitor.<br />
• The module is suitable for safety applications<br />
up to SIL 3 or PL e.<br />
• The S45F is also equipped with standard<br />
inputs and outputs, for functional switching<br />
of an actuator, for example.<br />
<strong>Siemens</strong> TIA Product Guide 2011<br />