<strong>Magnetic</strong> fields <strong>and</strong> tokamak plasmas<br />

Alan Wootton<br />

B<br />

B<br />

β I<br />

> 1 β I<br />

< 1<br />

R<br />

Figure 14.1. The toroidal field with different values of β I .<br />

R<br />

Measurements<br />

coil output<br />

Figure 14.2. A simple loop to measure toroidal flux.<br />

To measure δΦ it is usual to use a wire wrapped around the vacuum vessel, as in Figure 14.2.<br />

The voltage output from the coil is integrated to give a signal proportional to the enclosed flux.<br />

For most cases δΦ is small, typically ~ 1mWb, which must be compared to a typical vacuum flux<br />

Φ v = 1Wb enclosed by the same loop. There<strong>for</strong>e we have to use techniques which allow<br />

measurements to better than 1 part in 10 4 to get 10% accuracy in values of β I . This is done using<br />

compensating coils.<br />