<strong>Magnetic</strong> fields <strong>and</strong> tokamak plasmas<br />

Alan Wootton<br />

value <strong>for</strong> the decay index in the modeling is n = -0.2. We now compute the stable regions in<br />

(g,τ Σ space), the results of which are shown in Figures 21.2 through 21.5. For the values<br />

considered the best system is that of multipole sensing coils inside the vessel (Figure 21.2),<br />

closely followed by the single B θ coils inside the vessel (Figure 21.4). For sensing coils outside<br />

the vessel the operational space is restricted, more so in the case of single B θ sensors than <strong>for</strong><br />

multipole sensors. This is seen by comparing Figures 21.3 <strong>and</strong> 21.5.<br />

Figure 22.2. Moment coils, inside vessel.<br />

Figure 22.3. Moment coils outside vessel.<br />

Figure 22.4. Single B θ coils inside vessel. Figure 22.5. Single B θ coils outside vessel.<br />