TWINDOSE <strong>35</strong> – System for dishwashers<br />

2.5.3 Plumbing connections for the sanitizer pump (only on 3-pump systems).<br />

To install the sanitizer pump, proceed as follows:<br />

Suction<br />

• Insert the suction hose into the flat side of the stainless steel weight.<br />

• Insert the hose sticking out of the countersunk part of the stainless steel weight into the foot filter.<br />

• Secure the pipe by pushing the weight against the filter and rotating it until it matches perfectly (Figure 9).<br />

• Cut a sufficient length of sanitizer suction hose to reach the sanitizer pump.<br />

• Put the suction hose into the ring nut.<br />

• Insert the hose into the suction side of the sanitizer pump.<br />

• Tighten the fixing ring nut by hand on the suction side of the sanitizer pump.<br />

Stainless steel weight<br />

Fig. 9<br />

Suction hose<br />

Foot filter<br />

Delivery<br />

• Insert the delivery hose into the fixing ring nut on the injection valve.<br />

• Fix the hose to the injection valve.<br />

• Cut a sufficient length of delivery hose to connect it between the delivery side of the sanitizer pump (right) and the<br />

injection valve.<br />

• Tighten the ring nuts on the injection valve and the pump by hand.<br />

Fig. 10<br />

Always use the foot filter and make sure it reaches the bottom of the tank. Clean out any residue<br />

regularly.<br />