TWINDOSE <strong>35</strong> – System for dishwashers<br />
9 TROUBLESHOOTING<br />
9.1 THE POWER LED (POWER) DOES NOT SWITCH ON<br />
• Check the fuses in the circuits.<br />
• Check that the voltage at the circuit’s power terminals is correct. For details on the data plate and the<br />
connections diagram, refer to this manual.<br />
9.2 ONE OR MORE PUMPS ARE NOT RUNNING<br />
• Check the terminals on the circuit for the pump motor for any loose screws or disconnected wires.<br />
• Check that the voltage on the signal terminals is correct. For details on the data plate, refer to this manual.<br />
9.3 EXCESS DETERGENT<br />
• Check the voltage on the power supply to the system.<br />
• Check that the concentration set point was set correctly.<br />
• Make sure that there are no encrustation or foreign objects on the conductometric sensor that would<br />
compromise the correct reading of the concentration in the tank.<br />
• Make sure that the dosing time for the detergent pump has not been set at excessively high values.<br />
9.4 TOO LITTLE DETERGENT<br />
• Check the voltage on the power supply to the system.<br />
• Check that the concentration set point was set correctly.<br />
• Check the efficiency of the conductometric sensor.<br />
• Make sure that the dosing time for the detergent pump has not been set at excessively low values.<br />
• Check for possible chemical product leaks on the delivery line.<br />
9.5 EXCESS RINSE AID OR SANITIZER<br />
• Make sure that the dosing time or speed for the pump have not been set at excessively high values.<br />
9.6 TOO LITTLE RINSE AID OR SANITIZER<br />
• Make sure that the dosing time or speed for the pump have not been set at excessively low values.<br />
• Check for possible chemical product leaks on the delivery line.<br />
9.7 THE PUMP RUNS TOO SLOWLY<br />
• Check that the roller block has not seized.<br />
• Check lubrication of the flexible hose.<br />
9.8 LOSS OF PRIMING ON THE DOSING PUMP<br />
• Check the suction line for holes.<br />
• Check that the pump’s peristaltic hoses are not cracked or punctured.<br />
• Check that the peristaltic hoses are not worn.<br />
9.9 ERROR MESSAGES VIA THE LEDS ON THE FRONT PANEL<br />
Refer to paragraph 7.2 of this manual and if necessary contact your local dealer.<br />