TWINDOSE <strong>35</strong> – System for dishwashers<br />

9 TROUBLESHOOTING<br />

9.1 THE POWER LED (POWER) DOES NOT SWITCH ON<br />

• Check the fuses in the circuits.<br />

• Check that the voltage at the circuit’s power terminals is correct. For details on the data plate and the<br />

connections diagram, refer to this manual.<br />

9.2 ONE OR MORE PUMPS ARE NOT RUNNING<br />

• Check the terminals on the circuit for the pump motor for any loose screws or disconnected wires.<br />

• Check that the voltage on the signal terminals is correct. For details on the data plate, refer to this manual.<br />

9.3 EXCESS DETERGENT<br />

• Check the voltage on the power supply to the system.<br />

• Check that the concentration set point was set correctly.<br />

• Make sure that there are no encrustation or foreign objects on the conductometric sensor that would<br />

compromise the correct reading of the concentration in the tank.<br />

• Make sure that the dosing time for the detergent pump has not been set at excessively high values.<br />

9.4 TOO LITTLE DETERGENT<br />

• Check the voltage on the power supply to the system.<br />

• Check that the concentration set point was set correctly.<br />

• Check the efficiency of the conductometric sensor.<br />

• Make sure that the dosing time for the detergent pump has not been set at excessively low values.<br />

• Check for possible chemical product leaks on the delivery line.<br />

9.5 EXCESS RINSE AID OR SANITIZER<br />

• Make sure that the dosing time or speed for the pump have not been set at excessively high values.<br />

9.6 TOO LITTLE RINSE AID OR SANITIZER<br />

• Make sure that the dosing time or speed for the pump have not been set at excessively low values.<br />

• Check for possible chemical product leaks on the delivery line.<br />

9.7 THE PUMP RUNS TOO SLOWLY<br />

• Check that the roller block has not seized.<br />

• Check lubrication of the flexible hose.<br />

9.8 LOSS OF PRIMING ON THE DOSING PUMP<br />

• Check the suction line for holes.<br />

• Check that the pump’s peristaltic hoses are not cracked or punctured.<br />

• Check that the peristaltic hoses are not worn.<br />

9.9 ERROR MESSAGES VIA THE LEDS ON THE FRONT PANEL<br />

Refer to paragraph 7.2 of this manual and if necessary contact your local dealer.<br />

TWINDOSE <strong>35</strong> code 0000136655 rev. 1.0 40