TWINDOSE <strong>35</strong> – System for dishwashers<br />

<br />

RINSE SIGNAL<br />

DETERGENT PUMP<br />

The detergent pump is not controlled in this mode.<br />

RINSE AID PUMP<br />

When the signal from the solenoid valve, which controls the rinsing, is activated the rinse aid pump is activated in<br />

the time mode or in the speed mode, depending on how the DIP-switch 4 was set.<br />

• If it is set in the RINSE SPEED mode, the rinse aid pump will dose at the set speed using the potentiometer<br />

POT1 for the whole duration of the rinsing signal.<br />

• If it is set in the RINSE TIME mode, the rinse aid pump will dose at the maximum speed for the time set using<br />

the potentiometer POT1.<br />

In both cases, if the RINSE LIM ON mode is set using the DIP-switch 7, the rinse aid pump will stop dosing after 15<br />

seconds independently from the set time or from the duration of the RINSE SIGNAL. In order to de-activate this<br />

function, move the DIP-switch 7 to the left (RINSE LIM OFF)<br />

CAL. OFF<br />

CAL. ON<br />

.<br />

WARNING<br />

If the RINSE LIM ON mode is activated and the rinse aid pump is set in time for a duration of less than 15 seconds,<br />

the pump will dose for the set time using the POT1.<br />

SANITIZER PUMP (ONLY 3-PUMP VERSIONS)<br />

The sanitizer pump (optional) is activated simultaneously with the rinse aid pump only if the DIP-switch 6 is set in<br />

the “ON” position (SANI W/RINSE)<br />

CAL. OFF<br />

CAL. ON<br />

If DIP-switch 6 is set in the “OFF” position (SANI W/DET), the sanitizer pump will not be activated.<br />

TWINDOSE <strong>35</strong> code 0000136655 rev. 1.0 26