TWINDOSE <strong>35</strong> – System for dishwashers<br />

6.5 CONVEYOR DISHWASHING MACHINES – PROBELESS DOSING<br />

This mode is set using the DIP-switches in this configuration:<br />

CAL. OFF<br />

CAL. ON<br />

DETERGENT PUMP<br />

When the signal from the solenoid valve that controls the 1st charge signal is activated, the detergent pump doses<br />

for a time (between 0 and 255 seconds) set using potentiometer POT5 (DETER INIT CHRG).<br />

DETER<br />

INIT CHRG<br />

0 sec 255 sec<br />

The dosing time set will be completed even if the charge signal is de-activated during dosing.<br />

RINSE AID PUMP<br />

In this configuration, the rinse aid pump is not activated.<br />

SANITIZER PUMP (OPTIONAL)<br />

The sanitizer pump (optional) is activated simultaneously with the detergent pump only if previously set by moving<br />

DIP-switch 6 to the “OFF” position (SANI W/DET)<br />

CAL. OFF<br />

CAL. ON<br />

If DIP-switch 6 is set in the “ON” position (SANI W/RINSE), the sanitizer pump will not be activated.<br />

TWINDOSE <strong>35</strong> code 0000136655 rev. 1.0 34