TWINDOSE <strong>35</strong> – System for dishwashers<br />
6.3 SINGLE-TANK DISHWASHING MACHINES (DOOR)- PROBELESS DOSING<br />
This mode is set using the DIP-switches in this configuration:<br />
CAL. OFF<br />
CAL. ON<br />
<br />
CHARGE SIGNAL<br />
DETERGENT PUMP<br />
When the signal from the solenoid valve that controls the 1 st charge signal is activated, the detergent pump doses<br />
for a time (between 0 and 255 seconds) set using potentiometer POT5 (DETER INIT CHRG).<br />
DETER<br />
INIT CHRG<br />
The dosing time set will be completed even if the charge signal is de-activated during dosing.<br />
RINSE AID PUMP<br />
In this phase, the rinse aid pump is not activated.<br />
0 sec. 255 sec.<br />
SANITIZER PUMP (only 3-pump versions)<br />
The sanitizer pump (optional) is activated simultaneously with the detergent pump only if previously set by putting<br />
DIP-switch 6 in the “OFF” position (SANI W/DET)<br />
CAL. OFF<br />
CAL. ON<br />
If DIP-switch 6 is set in the “ON” position (SANI W/RINSE), the sanitizer pump will not be activated.<br />
TWINDOSE <strong>35</strong> code 0000136655 rev. 1.0 28